Copyright © 2016 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any
published technical data and instructions are subject to change without notice. Contact your McCrometer representative for current
technical data and instructions.
www.mccrometer.com
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078 Printed In The U.S.A. Lit. # 30122-40 Rev. 1.0 / 3-1-17
Page 4 of 19
™
FlowConnect
!
WARNING!
Never remove a meter or top plate assembly while the line is under pressure!
STEP 4: Remove the flow meter from the pipe
Remove the flow meter from the pipe as described in Section 3.0 of the Installation, Operation, and Maintenance (IOM)
manual for Mc Propeller Flow meters.
STEP 5: Remove the mechanical unit and base plate
a. Remove the six screws around the base.
b. Lift up and remove the canopy.
c. Loosen the pal nut (10019-00) from the base plate.
d. Unscrew and remove the register. Set it aside to be used
later.
e. Unscrew and remove the pal nut (10019-00) from
register. You will no longer need the pal nut and can
discard it.
f. Unscrew and remove the brass bushing (R0142-00)
from the base plate.
g. Lift up and remove the base plate from ell bracket.
b
x6
a
d
c
e
f
g