MCK 3000 

 

1.2 Terms of the warranty 

 

SUBJECT  OF  THE  WARRANTY:  the  warranty  is  applied  to  the  product  and  to 
those  parts  which  are  marked  with  the  serial  number  or  any  other identification 
number used by 

MC elettronica

 

DURATION  OF  THE  WARRANTY: 

MC  elettronica  S.r.l

.  guarantees  the 

MCK 

3000 Monitor 

for a period of 

1 year

 from the date of manufacture (printed on the 

identification label on the rear of the monitor) and the accessories for a period of 

1 year

The  warranty  covers  the  product  and  any  repairs  carried  out  within  the  agreed 
terms. 
This warranty does not apply in the event of: 

 

accidental damage; 

 

improper use; 

 

changes which have not been agreed upon, improper installation (or set-up); 

 

damage  caused  when  equipment  not  manufactured  by 

MC  elettronica

which is mechanically or electrically connected to our instruments, breaks or 
does not function properly; 

 

force  majeure  events  (lightning,  floods,  fire  or  other  causes  which  do  not 
depend on 

MC elettronica

). 

Repairs  under  warranty,  which  must  be  carried  out  in  the  laboratories  of  our 
authorised centres, are entirely free of charge provided the equipment is directly 
transported  to  said  laboratories  or  sent  carriage  free.  Transport  costs  and 
ensuing risks are entirely borne by the Customer. 
The  above-mentioned  warranty  is  valid  unless  otherwise  agreed  between 

MC 

elettronica

 and the Customer. 

!

 

Warning 
MC elettronica

 declines any liability for damage or direct or indirect costs 

caused  by  improper  use  or  inability  of  the  Customer  to  use  the 
equipment separately and/or together with other equipment. 

 

1.3 Service 

Service  is  available  in  all  the  countries  where  the  Computer  is  officially  supplied  by 

MC elettronica 

(during and after the warranty period). 

Any  kind  of  operation  that  is  to  be  carried  out  on  the 

MCK  3000  Monitor 

must  be 

done in accordance with the instructions stated in this manual or as agreed with 

MC 

elettronica

If not, the relative terms of the warranty might become null and void. 

Содержание AREA CONTROL MCK 3000

Страница 1: ...AREA CONTROL MCK 3000 UNIVERSAL HECTARE COUNTER FOR AGRICULTURAL MACHINERY USE AND ASSEMBLY INSTRUCTIONS NO 201211MI REV 2 EN...

Страница 2: ...ALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 201211MI Issued July 2012 Edition November 2020 MC elettronica S r l is not obliged...

Страница 3: ...6 4 Accessories 16 4 1 Standard accessories 16 5 Setting the work parameters 17 5 1 Setting the working width 17 5 2 Setting the calibration of the feed rate 17 5 3 Setting the number of divisions of...

Страница 4: ...ng the Monitor read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations The manual must be kept on the machin...

Страница 5: ...e majeure events lightning floods fire or other causes which do not depend on MC elettronica Repairs under warranty which must be carried out in the laboratories of our authorised centres are entirely...

Страница 6: ...ial worked area total worked area distance travelled speed Km h forecast of the hectares that will be worked in an hour only visible while you are working The Monitor uses a speed sensor to carry out...

Страница 7: ...Installation and use 7 MCK 3000 3 System installation Figure 2 Overall dimensions...

Страница 8: ...he bracket Figure 33 ref A and by means of two screws not supplied securely fasten the bracket to the structure fasten the Monitor to the bracket by screwing the supplied knobs Figure 33 ref B in the...

Страница 9: ...rear of the agricultural machine vehicle or by creating a metal reference protruding by at least 7 mm Figure 4 ref B2 We recommend installing the speed sensor inside the wheel and placing the sensor...

Страница 10: ...ts up as shown in the figure press keys and simultaneously 0 0 will appear on the Monitor cover 100 metres and the display will show the pulse count 1 2 3 etc once the 100 metres are covered confirm w...

Страница 11: ...point of the switch by changing the number of links in the chain Figure 5 Installing the sensor in the lower part of the bar If necessary the switch can also be secured to the upper part of the bar by...

Страница 12: ...the seed sensor in a stable way on the right or left side of the pipe using the bracket supplied with the lens facing the ground and the optical axis perpendicular to the ground at a distance of no m...

Страница 13: ...trimmer A is turned to the extreme hourly position 2 Turn the monitor on The RED LED B must be on otherwise enhance the orientation or move the seed sensor closer 3 Turn the trimmer A very slowly cloc...

Страница 14: ...the data relating to the working cycle The following elements can be seen on the panel REF DESCRIPTION A ON OFF key B LCD Display C Programming key D and keys E Forward speed forecast of workable hect...

Страница 15: ...s you to set the parameter selected at that moment using the and keys by the indicator arrow total work width calibration of the feed rate number of sectors in which to split the bar Display key allow...

Страница 16: ...ys the required parameters by the keys 3 Indicator arrows indicate the function selected for every key and 4 Accessories 4 1 Standard accessories Table 4 1 Standard accessories CODE DESCRIPTION PF0481...

Страница 17: ...ntered to be saved 5 2 Setting the calibration of the feed rate Set the calibration of the feed rate C number of pulses coming from the speed sensor every 100 metres covered by the machine by turning...

Страница 18: ...ount mode by turning the instrument on key and simultaneously pressing the and keys until parameter Ct appears on the display followed by a message indicating when the monitor will count the area The...

Страница 19: ...ATA PROGRAMMING Current year Settable range 00 99 step 1 default 00 Press to confirm the data Current month Settable range 01 12 step 1 default 01 Press to confirm the data Current day Settable range...

Страница 20: ...chanical counting sensor functions Check the operation of the mechanical sensor as follows 1 Turn the monitor on key 2 Select the partial total hectare display key 3 Pull the sensor chain so as to clo...

Страница 21: ...idth By pressing the key again the Monitor also eliminates the second sector and continues to count the area with only 1 3 of the working width By pressing the key again the Monitor restores the total...

Страница 22: ...he relative key must be kept pressed for more than 3 seconds and only with the machine stopped NOTE the totalisers are all independent of each other and therefore can be zeroed independently from each...

Страница 23: ...instrument Clean the instrument with a wet cloth and mild detergent to avoid erasing the serigraphs on the panel Warning Do not use pressurised water jets Do not use abrasive products or solvents Do...

Страница 24: ...cable is disconnected a Check the power cable SENSORS The speed sensor does not work a Broken cable b Calibration distance too long c Red part of sensor damaged a Restore connection b Adjust the cali...

Страница 25: ...chanical vibrations resistance 2 G Operating conditions Room temperature 20 C 75 C Weather conditions Relative humidity 90 Transport and storage Temperature 25 C 85 C 9 2 Accessory technical data 9 2...

Страница 26: ...MCK 3000 Installation and use MCK 3000 NOTES...

Страница 27: ...Installation and use 27 MCK 3000...

Страница 28: ...MCK 3000 Installation and use MCK 3000 Electronic equipment for agriculture earthmoving industry www mcelettronica it...

Отзывы: