OPERATION MANUAL 

FASK + ROI-3 

 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Thank you for choosing our Rogowski coils FASK and the associated measurement transducer 

ROI-3. 

 

Read these operating instructions carefully before installing the product! 

 

MBS AG · Eisbachstr. 51  Germany - 74429 Sulzbach-Laufen 

Technical support: +49 7946 9581-0 · Fax: +49 7946 9581-90 

E-Mail

[email protected]

 · Internet: 

http://www.mbs-ag.com

  

 
 
 

Changes and errors excepted 

 

 

Содержание FASK-100

Страница 1: ...ls FASK and the associated measurement transducer ROI 3 Read these operating instructions carefully before installing the product MBS AG Eisbachstr 51 Germany 74429 Sulzbach Laufen Technical support 4...

Страница 2: ...ns and indicates an electrical hazard This symbol is an addition to the safety instructions and indicates a po tential hazard This symbol with the word Note describes Procedures that do not pose any r...

Страница 3: ...national safety regulations as well as standard engineering practice Observe the installation instructions provided De energise the system before starting the work Check that it is de energised De en...

Страница 4: ...ic wire 1000V Measurement cat 1000V CATIII 600V CATIV FASK Technical data Model FASK 100 FASK 150 FASK 200 FASK 300 Coil length 395 mm 525 mm 665 mm 965 mm Window size 100 mm 150 mm 200 mm 300 mm Refe...

Страница 5: ...riptions FASK 100 FASK 150 FASK 200 FASK 300 A Window size A mm 135 165 210 310 B Window size B mm 100 150 200 300 C Outside diameter coil mm 151 181 226 326 D Coil diameter mm 8 E Connection cable le...

Страница 6: ...rement value 10 120 of rated current Frequency bandwidth 30 Hz up to 5 kHz Maximum burden per phase 0 5 Energy consumption 10 W Output 0A zero drift 0 01A Temperature coefficient 200 ppm K Weight 185...

Страница 7: ...g coil audibly latches Make sure that the measuring coil does not touch the power rail that is to be measured or a neighbouring rail because the maximum permissible temperature of the signal line is 8...

Страница 8: ...lity or guarantee is assumed for this choice The information in the catalogs and data sheets does not represent any assurance of special properties but results from empirical values and measurements L...

Страница 9: ...ent transformer inputs The 1 A outputs of the ROI 3 must not be earthed Likewise the input terminals of the measuring device must not be earthed energy meter I1 I2 I3 S1 S2 S1 S2 S1 S2 current measure...