mbnet Engineering ergo basic Скачать руководство пользователя страница 1

Art

.-Nr

.: 360 711   V

er

.: a

ergo basic

Operating Manual

internal cable feed

300° pivot range

height-adjustable

telescopic arm

Содержание ergo basic

Страница 1: ...Art Nr 360 711 Ver a ergo basic Operating Manual internal cable feed 300 pivot range height adjustable telescopic arm...

Страница 2: ...ss I Type BF with defibrillation protection indicating its compliance with the essential requirements regarding safety functionality and labelling of Annex I of the Medical Device Directive 93 42 EEC...

Страница 3: ...2 1 Preparation 13 4 2 2 Application of Electrodes 13 4 2 3 Before the Recording 13 4 2 4 During the Recording 13 4 2 5 Removal of Electrodes from the Skin 13 4 3 Electrode Identification and Colour C...

Страница 4: ...complete and legible Observe the operating and maintenance instructions 1 3 Indications for Use The device is an ECG cable arm and is operated in combination with normal ECG devices The device is suit...

Страница 5: ...Use with Electronics Operating the device with defective cables constitutes a danger to the life and limb of the patient Therefore take note of the following Damaged cable connections and connectors m...

Страница 6: ...enance intervals as stated in Chapter 6 Maintenance and Care have been complied with No further guarantees are assumed mbnet Engineering GmbH makes no warranty of merchantability or fitness for a part...

Страница 7: ...Symbols Used on the Device BF symbol no protection against defibrillation current Dispose of as electronic waste Attention consult accompanying documents Manufacturer Date of manufacture CE label Fol...

Страница 8: ...g heart potentials during resting and stress ECGs and sending the data to the ECG device 2 1 Elements of the Suction Device 2 1 1 Overview internal cable feed height adjustable telescopic arm 300 pivo...

Страница 9: ...module What makes the patient module stand out is its optimal user ergonomics The control panel is easy to clean 2 3 Joint The joint has a locking screw The joint is set from factory Adjust only when...

Страница 10: ...module Telescopic arm closure Open and close to extend and retract of the telescopic arm 2 5 Leads The tenshielded interference free electrode lines are trouble free and standout by virtue of their lo...

Страница 11: ...ted The device must not be used if it is suspected to be damaged Location The device must not be stored or operated in a wet humid or dusty area It must also not be exposed to direct sunlight or heat...

Страница 12: ...GmbH 2 To increase the electrode s conductivity and adherence Shave the areas where the electrodes are to be placed if necessary Thoroughly clean the areas with alcohol or soapy water skin cream is o...

Страница 13: ...e so that they are not frightened The patient must be lying down relaxed attention hands must be on the couch not in the air not be cold above all for resting ECG recordings No powerful devices must b...

Страница 14: ...hite green white brown white black white purple V1 V2 V3 V4 V5 V6 brown red brown yellow brown green brown brown brown black brown purple Neutral N black RL green 4 4 Resting ECG with 10 lead Patient...

Страница 15: ...e Mid axillary line on the same horizontal level as C4 L yellow LA black Left arm resting ECG R rot RA white Right arm resting ECG F green LL red Left foot resting ECG N black RL green Right foot rest...

Страница 16: ...N black RL green Right foot 5 Application Do not take an ECG picture until you have read and understood the safety instructions at the beginning of these instructions for use The device is a BF type...

Страница 17: ...ar checks see page 21 Chapter 6 4 The test results must be recorded in writing and compared to the values in the accompanying documents Maintenance work not described in this section may only be perfo...

Страница 18: ...stumbling over them or any damage being caused by the wheels of medical equipment carts When cleaning ensure that all labels and safety statements whether etched printed or stuck to the device remain...

Страница 19: ...cloth in the middle of the cable wipe 20 cm of the cable at a time with the cloth until the entire cable is clean Never clean the cable along its entire length at once as this can lead to damage to t...

Страница 20: ...nol 50 Propanol 70 80 Aldehyde 2 4 Ethanol 70 80 all products that are suitable for sensitive surfaces such as Bacillol 30 foam Bacillol 30 Tissues 10 Propanol 1 15 Propanol 2 20 Ethanol Mikrozid AF 2...

Страница 21: ...al condition Housing not damaged Electrode connector port not damaged Availability condition of accessories ECG suction hoses User guide Remarks Recurrent test in line with the information from the EC...

Страница 22: ...directly contact mbnet Engineering GmbH Please have your model name and serial number ready They are listed on the type label on the cable arm 6 5 Accessories and Consumables Always use mbnet Enginee...

Страница 23: ...990 1720 1845 1970 2 0 3 Bluetooth WLAN 802 11b g n LTE band 7 RFID2450 active and passive transponders and readingdevices 2400 2570 2450 2 0 3 WLAN 802 11a n 5100 5800 5240 5500 5785 2 0 3 Portable H...

Страница 24: ...ho are not authorized by the manufacturer If the electrical facility in the room in which the device is connected does not comply with the requirements of VDE 0100 710 If the instructions for use were...

Страница 25: ...1060 hPa 8 2 System Cable System cable length 2 1 m ECG connection 15 channel in accordance with IEC Standard Norm Control cable 1 5 m 8 3 Cable Arm Length 800 to 1100 mm Range of height adjustment 10...

Страница 26: ...II The manufacturer mbnet Engineering GmbH Kirschauer Stra e 37a OT Callenberg D 02681 Callenberg hereby declares that the product ergo basic Class I is in compliance with the following Directive 93 4...

Страница 27: ...User Guide ergo basic Seite 27...