background image

If  the  unit  is  equipped  with  the  optional  HEPA  after  filtration,  use  the  magnahelic  gauge  supplied  to  indicate  when  the  HEPA  filter  requires 
replacement.    The  HEPA  filter  is  not  cleanable  and  requires  replacement  when  the  magnahelic  gauge  reaches  2.5”  S.P.W.G.  If  equipped  the 
magnahelic gauge for the primary filter is located on the left side of the unit top panel and the HEPA magnahelic is located on the right side of the 
unit. 
Space Saver units have a cleanable cloth dust bag.  To clean this filter simply turn the machine off and taking a handful of cloth located about 1 foot 
below the bag top, shake the bag for about 10 seconds in a rapid back and forth direction.  This will release any dust collected on the inside of the 
dust bag dropping the dust into the collection pail.  It is not necessary to empty the collection pail until the pail is full.  Clean the filter on a regular 
time interval determined by the dust load and reduced machine airflow. 
 
Refer to the operator’s manual for primary and HEPA filter replacement. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TORNADO

Страница 1: ...t Pressure Light Duty Production Dust Collectors Pollution Benches 591 W Apollo St Brea CA 92821 714 257 0484 714 257 0184 fax mbasales mediablast com e mail OPERATOR S MANUAL PC Work Bench TORNADO PC PCE Space Saver Tornado Workbench and Workstation ...

Страница 2: ...ower assemblies THREE PHASE ELECTRICAL Check all three phase blower installations for proper blower rotation It is necessary during installation of any three phase single power source blower upgrade to make sure and check for proper blower rotation The exhaust blower will move 1 3 cfm capacity during reversed rotation MACHINE OPTIONS INCLUDE ELECTRICAL CORD LOCK OUT AND ELECTRICAL DISCONNECT Custo...

Страница 3: ...proper rotation if the unit includes high voltage electrical upgrade package The machine is now almost operational Turn the machine on off switch to the on position The switch is located on the right side of the cabinet All Space Saver units have the switch located in the machine leg right side Place the parts to be processed on the operator bar grate The front grate assembly is the main air intak...

Страница 4: ...t side of the unit Space Saver units have a cleanable cloth dust bag To clean this filter simply turn the machine off and taking a handful of cloth located about 1 foot below the bag top shake the bag for about 10 seconds in a rapid back and forth direction This will release any dust collected on the inside of the dust bag dropping the dust into the collection pail It is not necessary to empty the...

Страница 5: ... Safety Glasses 4 No Smoking Area 5 SERVICE 8 Minimum Recommended Maintenance Schedule 8 Primary Filter Replacement 8 HEPA Filter Replacement cabinet option 8 Dust Pan Removal 9 Light Bulb Replacement 9 TROUBLE SHOOTING YOUR TORNADO 15 PARTS LIST SYSTEMS DIAGRAMS 20 TABLE OF CONTENTS ...

Страница 6: ... and tag out procedures before connecting any electrical portion of this machine The end user shall provide the appropriate means of disconnecting and locking off the electrical to this machine OPERATION ALWAYS WEAR SAFETY GOGGLES AND EAR PROTECTION WHEN OPERATING ANY MACHINE The Tornado workbenchs have been designed for the collection of nuisance dust created by jobs involving grinding polishing ...

Страница 7: ...ge is supported at the rear with a centering ring located on the open sealing end of the filter cartridge After removing the tightening knob slide the filter cartridge from the unit Replace with new filter cartridge making sure to center the filter on the rear centering ring and insert the tightening rod through the filter cartridge end cap NOTE Each time the cartridge is replaced always replace t...

Страница 8: ...t provided as an approved method of protective encasement for disposal of hazardous waste Please follow all Federal State and local laws pertaining to hazardous waste disposal Remove the new HEPA filter from the shipping box NOTE Be certain not to bump the packing into sharp objects that may tear the packing material Place the HEPA filter inside the filter housing with the gasket pointed down When...

Страница 9: ...TORNADO Single Cartridge Units 26 25 24 18 7 1 8 9 10 17 16 12 28 30 27 31 8 8 8 3 3 8 8 ...

Страница 10: ...lable 70 00 12 108 06 061 106 001 Plastic Light Shield for 108 09 003 10 00 12 108 09 013 Light Fixture Hazardous Duty 2 Bulb 125 00 12 108 06 104 Light Cover Hazardous 60 00 16 100 08 141 Thumb Screw 4 50 17 100 09 100 NEMA Electrical Enclosure single power source 90 00 17 100 09 031 Transformer 60 00 17 100 09 103 Motor Contactor 65 00 17 100 09 059 120V Fuse 1 AMP 10 00 17 100 09 104 Adjustable...

Отзывы: