3. Connect a battery charger to the battery and adjust the charging current as follows.
Battery slow charge current
80D26L (55): 5.5-6.5 A
Battery quick charge current [30 min]
80D26L (55): 35 A
4. After the battery is recharged, verify that the voltage is within the specification and remains at the same
value for
1 h or more
after the recharging has been completed.
z
If not within the specification, replace the battery.
Standard voltage
12.4 V or more
Fig. 4: Connecting Battery Charger To Battery
Courtesy of MAZDA MOTORS CORP.
GENERATOR REMOVAL/INSTALLATION [MZI-3.5]
1. Disconnect the negative battery cable.
2. Drain the engine coolant. (see
ENGINE COOLANT REPLACEMENT [MZI-3.5]
.)
3. Remove the air cleaner and fresh air duct component. (see
INTAKE-AIR SYSTEM
WARNING:
z
Remove and install all parts when the engine is cold, otherwise they
can cause severe burns or serious injury.
z
When the battery cables are connected, touching the vehicle body
with generator terminal B will generate sparks. This can cause
personal injury, fire, and damage to the electrical components.
Always disconnect the negative battery cable before performing the
following operation.
2007 Mazda CX-9 Grand Touring
2007 ELECTRICAL Charging System (MZI-3.5) - CX-9
Microsoft
Sunday, November 15, 2009 9:29:33 AM
Page 5
© 2005 Mitchell Repair Information Company, LLC.