CATALYST PELLETS & MODIFICATION OF SECONDARY AIR SYS
Article Text (p. 14)
1983 Mazda RX7
For www.iluvmyrx7.com
Copyright © 1998 Mitchell Repair Information Company, LLC
Saturday, September 08, 2001 09:59AM
Fig. 14: Location of Drain Plugs No. 1 and 2
2. Hold the converter in a vise at an angle of 25
ø
-30
ø
as shown
in Fig. 15.
Fig. 15: Proper Positioning of Converter in a Vise
3. Put the funnel provided in the drain hole No. 1 (front side).
4. Pour all the pellets from the plastic bag containing a larger
amount of pellets (1.4 L) into the drain hole No. 1.
5. Tap the converter repeatedly at point "A" (see Fig. 15) with
a plastic hammer to allow the pellets to flow in until no
more pellets can be put in.
6. Hold the converter level in the vise. See Fig. 16.