Содержание WED9051YW0

Страница 1: ...t Vent 18 Level Dryer 18 COMPLETE iNSTALLATiON CHECKLIST 19 DOOR REVERSAL 19 STACKING WASHER AND DRYER 19 TROUBLESHOOTING 19 iNSTALLATiON NOTES Date of purchase Date of installation installer Model number Serial number Para obtener acceso al manual de uso y cuidado en espaSol o para obtener informaci6n adicional acerca de su producto visite www whirlpool com Tenga listo su nOmero de modelo complet...

Страница 2: ...ential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING i ofFi Clothes dryer installation must be performed by a qualified installer install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting materials or fle ible metal foil type du...

Страница 3: ...easure Pliers Parts package is located in dryer drum Check that all parts are included NOTE If installing dryer on pedestal do not use leveling legs Optional Equipment Not supplied with dryer Refer to your Use and Care Guide for information about accessories available for your dryer Parts needed Not supplied with dryer Check local codes Check existing electrical supply and venting See Electrical R...

Страница 4: ...may use the water supply for your washer using the Y connector and short hose if needed which are provided 20 100 psi 138 690 kPa for best performance Level floor with maximum slope of 1 25 mm under entire dryer If slope is greater than 1 25 mm install Extended Dryer Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For e...

Страница 5: ...wed with tested spacing of 0 0 mm clearance on sides and rear Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing should be considered on all sides of the dryer to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the d...

Страница 6: ...n both sides of the line Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Electrical Connection To properly install your dryer you must determine the type of electrical connection you ...

Страница 7: ...viding a path of least resistance for electric current This dryer is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Che...

Страница 8: ...ire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten ail electrical connections Failure to do so can result in death fire or electrical shock Electrical Connection Options 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to Power Supply Cord Connection Power supp...

Страница 9: ...ain relief screws at this point if your outlet looks like this Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on this page if your outlet looks like this Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 Wire Power Supply Cord Connection on page 10 4oWIRE POWER SUPPLY CORD CONNECTION iMPORTANT A 4 wire connection is required for moble home...

Страница 10: ...LY CORD CONNECTION Use where local codes permit connecting cabinet ground conductor to neutral wire 3 wire receptacle NEMA type 10 30R 3 prong plug Spade terminals with upturned ends 10 Ring terminals Remove center terminal block screw B Connect neutral wire Connect neutral wire white or center C of power supply cord to center terminal block screw B Tighten screw Connect remaining wires Connect re...

Страница 11: ...overing from end of cable leaving bare ground wire at 5 127 mm Cut 11 2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks Attach hooked wires to terminal block Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief screw against the direct wire cab...

Страница 12: ...25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape wire ends into hooks Attach hooked wires to terminal block Connect ground wire green or bare F of direct wire cable to external ground conductor screw A Tighten screw Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hoo...

Страница 13: ... method is acceptable before connecting Prepare to connect neutral ground wire and neutral wire _ A Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A Connect neutral ground wire and neutral wire Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw ...

Страница 14: ...duced airflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Charts and if necessary modify exis...

Страница 15: ...t Do not use a metal foil vent Failure to follow these instructions can result in death or fire If you prefer dryer may be converted to exhaust out right side left side all models except WED9051Y or through bottom You must contact your local dealer to have dryer converted NOTE On Model WED9051Y only do not exhaust out the left side Special provisions for mobile homes Exhaust vent must be securely ...

Страница 16: ... 7 m 1 Rigid metal 54 ft 16 5 m 48 ft 14 6 m 2 Rigid metal 44 ft 13 4m 38 ft 11 6m 3 Rigid metal 35 ft 10 7 m 29 ft 8 8 m 4 Rigid metal 27 ft 8 2 m 21 ft 6 4 m Long Vent System Chart Number of Type Box Iouvered Angled 90 elbows of vent hoods hoods 0 Rigidmetal 130 ft 39 6 m 129 ft 39 3 m 1 Rigid metal 125 ft 38 1 m 119 ft 36 3 m 2 Rigid metal 115 ft 35 1 m 109 ft 33 2 m 100 ft 30 5 m 92 ft 28 0 m ...

Страница 17: ...tach Y connector to brass male end of the short hose Screw on coupling by hand until it is seated on connector 3 Tighten couplings Attach long hose to Y connector and tighten couplings One end of the long hose has a wire mesh strainer inside the coupling Attach this end to the Y connector Attach washer cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on con...

Страница 18: ...ove cardboard from under dryer LEVEL DR_R fl Level Dryer Place level here Check levelness of dryer from side to side Repeat from front to back NOTE The dryer must be level for the moisture sensing system to operate correctly Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside ...

Страница 19: ...me the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to the need for certain part replacement or repair _ Select a Time Dry heated cycle and start dryer Do not select Air Only Temperature setting If dryer will not start check the following Controls are set in a running or On position Start button has been p...

Страница 20: ...W10443041A W10443042A SP 2011 All rights reserved 11 11 Printed in U S A ...