5
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas
pressure does not exceed 13" (33 cm) water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas company
personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Without the correct gas supply, your dryer may tumble the
clothes, but will not dry the clothes. For more information,
see Installation Instructions section of Use and Care Guide.
1
1
2
2
3
5
Plug into a grounded 3 prong outlet.
Clean the lint screen before
every load.
6
6
3
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or fire.
Existing vent should be cleaned before connecting dryer
and then every two years for best performance.
4“
(10.2 cm)
Replace plastic vent with rigid
metal or flexible metal vent.
Vent should be 4" (10.16 cm) wide.
1
Check that all four legs are
installed.
Use a wrench to finish turning the
legs until the diamond mark is no
longer visible.
Be sure dryer is level side to side
and front to back.
Adjust the legs as needed.
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
Use clamps to seal all joints. Do
not use duct tape or screws.
Make the vent as short as possible
with the fewest number of turns.
If using existing vent, remove lint
from the entire length of vent.
Remove lint from hood. Flapper or
louvers should move freely.
TIPS FOR BEST PERFORMANCE OF GAS DRYER
See Installation Instructions for more detailed information.
Correct
venting
2
A level
dryer
3
Proper
gas
supply
for dryer
Open
Closed
For LP gases, the burner must be
converted. Conversion must be
made by a qualified technician.
There must be a gas line and
shutoff valve within 6' (1.8 m) of
the dryer’s final location.
After proper installation the gas
line must be open.
Number of 90° turns or elbows
Type of vent
Box or louvered hoods
Angled hoods
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
Use the Vent System Chart below to determine type of vent material and hood
combination acceptable to use.
NOTE: Performance of rear exhaust to either side of the dryer is equivalent to adding
one elbow. To determine maximum exhaust length, add one elbow to the chart.
Vent System Chart
W10160248A
MAYTAG and the “M” Symbol are registered trademarks of Maytag Limited in Canada.
© 2007 All rights reserved.
All other marks are trademarks of Maytag Corporation or its related companies.
Printed in U.S.A.
NOTE: The following kits for alternate installations
are available for purchase. For further information,
please call 1-800-688-9900. In Canada,
call 1-800-807-6777.
• Rear exhaust installation to left or
right side: Part Number 4396011
• Over-the-top installation:
Part Number 4396028
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
10/07
™
4
4
4
Connect to cold water supply. For more
information, see Installation Instructions
section of Use and Care Guide.
Cold water inlet hose
to the washer.