27" Wide Electric Dryer 

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

MEDX700X

Electrical

This dryer requires a 3 or 4 wire, single 

phase, 120/240 volt, 60 Hz., AC only electrical supply 

(or 3 or 4 wire, 120/208 volt electrical supply, if speci-

fied on the serial/rating plate) on a separate 30-amp 

circuit, fused on both sides of the line. A time-delay 

fuse or circuit breaker is recommended. Connect to 

an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

The vent system chart provides venting requirments 

that will help to achieve the best drying performance.

Vent system chart:

  

NOTE:

 Side and bottom exhaust installations have  

a 90° turn inside the dryer. To determine maximum  

exhaust length, add one 90° turn to the chart.

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

Dryer dimensions

Select the route that will provide the straightest and 

most direct path outdoors. Plan the installation to 

use the fewest number of elbows and turns. Use the 

fewest 90° turns possible.

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10115226B 

01/2011

Do not use vent runs longer than specified in vent 

length chart. Determine the number of elbows you 

will need.

43"

(1092 mm)

*29

1

/

2

"

(749 mm)

27"

(687 mm)

A

23¾"

(603 mm)

43"

(1092 mm)

27"

(687 mm)

*29

1

/

2

"

(749 mm)

13¾"

(349 mm)

B

A. Large opening side-swing door

B. Wide opening hamper door

 

A

B

C

    18"*

(457 mm)

  1"

(25 mm)

27"

(686 mm)

        1"

   (25 mm)

        1"*

    (25 mm)

14" max.*

(356  mm)

 

  29

¼"

(743 mm)

   

5

½"*

 (140 mm)

  48 in.

  

(310 cm )

2

*

2

  

24 in.

(155 cm )

*

2

       

3"*

(76 mm)

       

3"*

(76 mm)

Minimum required spacing for recessed or closet installation

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Additional spacing recommended

The dimensions shown following are for the minimum spacing allowed.

Additional spacing should be considered for ease of installation and servicing.

 

Additional clearances might be required for wall, door, and floor moldings.

 

Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to 

 

reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and 

 

bottom of the door are required.  
Louvered doors with equivalent ventilation openings  
are acceptable.
Companion appliance spacing should also be considered.

 

The location must be large enough to allow the dryer door to open fully.

 

Vent System Chart

Number of 

90° turns  

or elbows

Type  

of vent

Box/louvered 

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)