  Steam and Non-Steam Electric Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

Electrical

This dryer requires a 3 or 4 wire, single 

phase, 120/240 volt, 60 Hz., AC only electrical 

supply (or 3 or 4 wire, 120/208 volt electrical supply, 

if specified on the serial/rating plate) on a separate 

30-amp circuit, fused on both sides of the line. A time-

delay fuse or circuit breaker is recommended. Connect 

to an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.

Water

 

(Steam models only)

The dryer must be  

connected to the cold water faucet using new inlet 

hoses. Do not use old hoses. Do not overtighten.  

Damage to the coupling can result.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

The vent system chart provides venting requirments 

that will help to achieve the best drying performance.

Vent system chart:

  

NOTE:

 Side and bottom exhaust installations have  

a 90° turn inside the dryer. To determine maximum  

exhaust length, add one 90° turn to the chart.

   

4"

(102 mm)

2½"

(64 mm)

     

4"

(102 mm)

      

4"

(102 mm)

B

A

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

 27"

(686 mm)

38"

(965 mm)

NON-STEAM - 51

1

/

2

"

(1308 mm)

STEAM - 52

9

/

16

"

(1335 mm)

NON-STEAM - 31

1

/

2

"

(800 mm)

*STEAM - 32

9

/

16

"

(827 mm)

 

 27"

(686 mm)

38"

(965 mm)

1"*

(25 mm)

1"*

(25 mm)

NON-STEAM - 5"** 

(127 mm)

STEAM - 5

1

/

2

"**

(140 mm)

NON-STEAM - 31

1

/

2

"

(800 mm)

STEAM - 32

9

/

16

"

(827 mm)

 27"

(686 mm)

 14" max.

(356 mm)

 18" max.

(457 mm)

1"

(25 mm)

1"

(25 mm)

76"

(1930 mm)

6"

(152 mm)

3"

(76 mm)

3"

(76 mm)

48 in.

*

(310 cm

2

)

24 in.

*

(155 cm

2

)

5"

(127 mm)

NON-STEAM - 31

1

/

2

"

(800 mm)

STEAM - 32

9

/

16

"

(827 mm)

 14"* max.

(356 mm)

9"*

(229 mm)

7"*

(178 mm)

7"*

(178 mm)

 18"* max.

(457 mm)

 27"

(686 mm)

1"*

(25 mm)

1"*

(25 mm)

14"

(356 mm)

3

7

/

16

"

(87 mm)

1"

(25 mm)

7

5

/

8

"

(194 mm)

3

3

/

8

"

(86 mm)

1"

(25 mm)

Custom undercounter installation-dryer only

Dryer dimensions

† Most installations require a minimum  

5" (127 mm) clearance behind the dryer for 

the exhaust vent with elbow. See Installation 

Instructions, “Venting Requirements.”

Back View

Side View

Select the route that will provide the straightest and most direct path outdoors.  

Plan the installation to use the fewest number of elbows and turns.  

Use the fewest 90° turns possible.Do not use vent runs longer than specified in vent 

length chart. Determine the number of elbows you will need.

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10255468C

05/2010

For closet installation, with a door, the minimum ventilation openings in the top  

and bottom of the door are required. Louvered doors with equivalent air ventilation  

openings are acceptable.

For cabinet installation, with a door, the minimum ventilation openings in the top  

are required.

 *Required spacing  **For side or bottom venting, 0" (0 mm) spacing is allowed.