43 ½"

(110.5 cm)

*29 ¼"

(74.3 cm)

22¼"

(56.5 cm)

29"

(73.7 cm)

B

C

        1" 

    (2.5 cm)

14" max.*

(35.6 cm)

   29-1/4"

(74.3 cm)

   5"*

 (12.7 cm)

  48 in.  

(310 cm  )

2

*

2

  24 in.
(155 cm  )

2

*

2

       3"*

(7.6 cm)

       3"*

(7.6 cm)

*

A

    18"*

(45.7 cm)

  1"

(2.5 cm)

       

29"

(73.7 cm)

        

1"

   (2.5 cm)

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

EXHAUST VENTING

MED6300T

MED6400T

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10088777

10-15-07

RECESSED AREA AND CLOSET INSTALLATION

For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
in the top and bottom are acceptable.

A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents

NOTE: 

Side and bottom exhaust installations have a 90

°

 turn 

inside the dryer. To determine maximum exhaust length, add one 
90

°

 turn to the chart.

Number of 
90

°

 turns 

or elbows

Type of
vent

Box or 
Louvered 
hoods

Angled
hoods

0

Rigid

 metal

Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid

 metal

Flexible metal

54 ft (16.5 m) 
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid

 metal

Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid

 metal

Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid

 metal

Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

A .  Louvered hood style 

B .  Box hood style 

      4" 
(10.2 cm) 

      4" 
(10.2 cm) 

Recommended hood styles

Angled hood style is

acceptable.

Select the route that will provide the straightest and most direct path
outdoors.  Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.  

Do not use vent runs longer than specified in vent length chart.

Determine the number of elbows you will need.

Electric Dryer

* Most installations require a minimum 5”

(12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See Installation
Instructions, “Venting Requirements.”

Electrical:

A 3 or 4 wire, single phase, 120/240

volt, 60 Hz, AC only electrical supply (or 3 or 4
wire, 120/208 volt electrical supply, if specified on
the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit. Do not
have a fuse in the neutral or grounding circuit. 

Exhaust venting:

Exhaust your dryer to the

outside. 4" (10.2 cm) diameter vent is required.
Heavy metal exhaust vent and clamps must be
used. Do Not use plastic or metal foil vent.
Exhaust hood must be at least 12" (30.5 cm) from
the ground or any object that may be in the path of
the exhaust.

  4" 

(10.2 cm) 

2.

½"

(6.4 cm) 