background image

Technical Information- Dishwasher

 

May 2004 

16023063 

©2004 Maytag Services 

JDB4000AWB JDB4000AWQ  JDB4000AWS JDB4000AWW 
MDB5600AWB MDB5600AWQ  MDB5600AWS MDB5600AWW 

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or 
repair of this unit.  Refer to Service Manual 16021814. 

CAUTION

!

 

All safety information must be followed as provided in Service Manual 16021814. 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless 
testing requires power. 

 
 

Specifications JDB4000AW* 

MDB5600AW*

Benefits  JDB4000AW* 

MDB5600AW*

Power Source

 

Wash cycles 

Voltage AC 

120 VAC 

120 VAC 

Heavy Wash 

Amperage (Single Unit) 

15 A 

15 A 

Normal Wash 

Frequency 

60 Hz 

60 Hz 

Light Wash 

Motor horsepower 

1/3 

1/3 

Rinse Only 

Receptacle N/A 

N/A 

Drying 

System 

Plug N/A 

N/A 

Features 

Dimensions

 

QuietSeries 100™ 

Height

overall 

33 ½” to 35 ¼”  33 ½” to 35 ¼”  2/4/6 Hour Delay 

Start 

X X 

Width 

23 7/8” 

23 7/8” 

*ToughScrub™ 

Depth 

23 1/2” 

23 1/2” 

*Extra Rinse 

Weight

 

*Sanitizer X 

Un-crated 

65 lbs. 

65 lbs. 

Control Lock 

Automatic Temp 
Control 

X X 

Energy Star 

Active Vent Dry 

Finer Filtration 

Hard Food 
Disposer 

X X 

 

10 Touch Pad 
Controls 

X X 

*On selected models only 

Содержание JDB4000AWB

Страница 1: ...g unless testing requires power Specifications JDB4000AW MDB5600AW Benefits JDB4000AW MDB5600AW Power Source Wash cycles 4 4 Voltage AC 120 VAC 120 VAC Heavy Wash X X Amperage Single Unit 15 A 15 A Normal Wash X X Frequency 60 Hz 60 Hz Light Wash X X Motor horsepower 1 3 1 3 Rinse Only X X Receptacle N A N A Drying System X X Plug N A N A Features Dimensions QuietSeries 100 X X Height overall 33 t...

Страница 2: ...Motor Main yellow See Component Specifications Motor Connections for details 3 to 4 Ω Control Board See Component Specifications Membrane Readings for troubleshooting pin out instructions Water valve 120V 60hz 7 watts 1 13 10 gpm at 20 120 psi Measure resistance from J6 Pin 4 Aqua Float switch to ST4 Black Common 1 1 k Ω This value assumes the float switch is closed Vent wax motor 120V with 1 4 ac...

Страница 3: ...ture drop 164 F 4 F Temp 0 Ω Closed Infinite Ω Open Sensor Thermistor 10KΩ 3 at 77 F and 2 4 k Ω 6 5 at 140 F J5 pin 1 Orange Temp to J5 Pin 4 Red Neutral Infinite Ω Open 0 Ω Closed Heater Heating Element 120v 60hz 650 watts 5 in air 830 watts 5 in coldwater Measure resistance from ST1 Red Black Heater to ST11 White Common 16 Ω This value assumes the high limit thermostat is closed Drain Motor 120...

Страница 4: ...in 8 Pin 10 Pin 5 Pin 10 Pin 6 Pin 10 Pin 7 Pin 11 Pin 5 Pin 11 Pin 6 Pin 11 Pin 7 Pin 10 Pin 8 Pin 11 Pin 8 Pin 12 Pin 7 Field Service Test A Field Service Test may be started by pressing the key 5 times followed by the key within 6 seconds This test must be performed with clean water to insure proper sensor performance 88 will appear in the display if available and the following sequence of even...

Страница 5: ...osed Use the Manual Function Test as described on the electrical schematic sheet 6 918139 to check components before opening the door to perform continuity testing or replacing parts To check continuity from ends of power leads to control board through door switches A white plastic latch must be inserted in the latch assembly for this test With one ohm meter lead connected to the white neutral pow...

Страница 6: ...hock personal injury or death disconnect power to dishwasher before servicing unless testing requires power 16023063 6 May 2004 2004 Maytag Services Blue Common Yellow Main Green Ground Red Start 1 3HP 120V 60hz 3 2 amps 3250 RPM Wire harness Connection plug ...

Страница 7: ...U PU PU BK BK BK BK BK BK BK BK BK BK BK BK OR OR BK RD RD RD RD AQ AQ AQ AQ LI N DOOR SWITCH LI DOOR SWITCH N HEATER DISPENSER VENT DRAIN MOTOR FLOAT SWITCH THERMOSTAT WATER VALVE WASH MOTOR START GROUND OVERLOAD MAIN MOTOR CAPACITOR HINGE TUB SHIELD TERMINAL BOX OR PU RD AQ SENSOR THERMISTOR These parts are present on models with 3 racks Component Information Wash Motor 1 3 HP motor 120V 60hz 3 ...

Страница 8: ...36 min 1 46 max RINSE 5 00 DRAIN 2 00 FILL 0 02 Note If is not selected the heater will not be activated during the dry cycle Heated Dry DRY CYCLE 160 Wash Models without option HEATER ON 3 00 HEATER OFF 1 30 HEATER ON 1 00 HEATER OFF 1 30 HEATER ON 1 00 VENT CLOSED VENT OPENED HEATER ON 1 00 HEATER ON 1 00 HEATER ON 1 00 HEATER ON 1 00 HEATER ON 1 00 HEATER OFF 1 30 HEATER OFF 1 30 HEATER OFF 1 3...