Страница 1: ... Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use Gas Dryer Installation Instructions art No 3395325 Rev A 3 73 ...

Страница 2: ...as checked by a qualified person before installing the dryer The L P gas supply must not exceed a pressure of 13 water column l New flexible tubing should be used Reusing old flexible tubing might result in possible leaks or fire hazard Failure to follow these instructions may result in fire or explosion OBSERVE ALL GOVERNING CODES AND ORDINANCES I A n First make certain that this drver is equippe...

Страница 3: ... lint could result in a fire or cause moisture damage l Exhaust the dryer outside to prevent exposure to substances in the gas fuels and combustion which may be harmful to your health The moisture and lint indoors may cause FIRE HAZARD from lint collected in dryer Moisture damage to woodwork furniture paint wallpaper carpet etc House cleaning problems and possible health problems Failure to follow...

Страница 4: ... position 5 n Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 10 n Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks dryer run for at least five minutes If the timer control knob 6 n With one of the burner does not ignite and you can feel...

Страница 5: ... If dryer does not operate properly If dryer will not operate check to be sure that A Electrical supply is connected B The house fuse has not blown or circuit breaker has not tripped C Door is closed D Controls are set in a running or ON position E Start button has been pushed firmly F Gas supply line shutoff valve is open When moving the dryer l Disconnect the power supply cord and tape securely ...