Страница 1: ...ch Park Quincy MA 02269 A three wire single phase AC 120 240 volt or 120 208 volt 60 Hz electrical system properly fused to meet NFPA No 70 must be provided The oven circuit should be fused with a 30 ampere fuse if it is the only unit on the circuit Size No 10 wire minimum may be used if the oven is the only appliance on the circuit If smaller sizes of wire are used the unit efficiency will be red...
Страница 2: ...er s Manual for operating instructions and warranty 7 Packed with this unit is an additional bottom trim to cover the bottom edge of the cabinet cutout If needed loosen the screws on the underside of the front closure and slip trim in place with the solid flanged side down Retighten screws TRIM J_ CAtqN_r j 27 24 CAUTION If cabinet doors are provided above wall oven a minimum spacing of 3_ t is re...