4-33
1. The door lock has a manual release lever
on the left side of the door lock. Remove
the front panel and push the lever down to
manually unlock the door.
2. To remove the door lock, remove the front
3. Remove four #4 hex screws securing the
door lock behind the ornament panel.
4. It may be necessary to loosen the two T-30
screws on the left side of the ornament
panel, above and below the door lock.
5. Pull the ornament panel forward just
enough to slide the door lock out from
behind it.
6. To disconnect the wire harness from the
door lock, push the locking tab away from
the plug, and pull plug out of the connector.
nOTe:
The wire harness is available as a
separate part.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
DOOr LOCK
Manual
Release Lever
Two T-30
Screws
Locking
Tab