4-26
1. To remove the service switch, open the
control panel (See page 4-18).
2. Remove two T-20 screws from the top of
the control panel, securing the mounting
bracket for the service switch.
3. Lift the switch and mounting bracket out of
the control panel.
4. To remove the switch, remove two T-10
screws securing switch to mounting bracket.
5. Disconnect the two wire connectors from
the service switch.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.