Module model
Specific construction
Marking
MSXXXM-72
MSXXXP-72
MSXXXMB-72H
Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned
Module Fire Performance:
Type 1/ Type 2
MSXXXM-60
MSXXXP-60
MSXXXMB-60H
Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned
Module Fire Performance:
Type 1/ Type 2
MSXXXM-36
MSXXXP-36
Please check the related IEC description
files when checking the fire protection rank
of the BOM concerned
Module Fire Performance:
Type 1/ Type 2
MSXXXMB-6 6H
MSXXXMB-5 7H
Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned
Module Fire Performance:
Type 1/ Type 2
MSXXXMB-55H
MSXXXMB-5 4H
Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned
Module Fire Performance:
Type 1/ Type 2
MSXXXMB-5 0H
MSXXXMB-40H
Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned
Module Fire Performance:
Type 1/ Type 2
All series in this
description
All construction in this description
Fire resistance rating: Class C
The Type 1 and/or Type 2 modules with the specified constructions in the table below, when installed
with an IEC listed mounting system that has been rated as a Class A System, is suitable to maintain the
System Class A Fire Rating.
The fire rating of the module is valid only when mounted in the manner specified in the mechanical
mounting instructions .
4.
Product Information
4.1 Unpacking and storage
At time of receipt, verify that the product delivered is in fact the product ordered. Carefully check the product
name and subname. Leave the product in its original packing box until you are ready to install.
Store packing boxes in a clean, dry area with relative humidity below 85% and ambient temperatures between -
20°C and 50°C.
Do NOT stack more than the maximum amount of allowable pallets on top of each other.
At the installation site, take care to keep modules and particular their electrical contacts clean and dry
before installation. If connector cables are left in damp conditions then the contacts may corrode. Any module
with corroded contacts should not be used.