Module model

Specific construction

Marking

MSXXXM-72
MSXXXP-72
MSXXXMB-72H

Please check the related IEC description files when

checking the fire protection rank of the BOM
concerned

Module Fire Performance:
Type 1/ Type 2

MSXXXM-60
MSXXXP-60
MSXXXMB-60H

Please check the related IEC description files when

checking the fire protection rank of the BOM
concerned

Module Fire Performance:
Type 1/ Type 2

MSXXXM-36
MSXXXP-36

Please check the related IEC description

files when checking the fire protection rank
of the BOM concerned

Module Fire Performance:
Type 1/ Type 2

MSXXXMB-6 6H
MSXXXMB-5 7H

Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned

Module Fire Performance:
Type 1/ Type 2

MSXXXMB-55H

MSXXXMB-5 4H

Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned

Module Fire Performance:
Type 1/ Type 2

MSXXXMB-5 0H

MSXXXMB-40H

Please check the related IEC description files when
checking the fire protection rank of the BOM
concerned

Module Fire Performance:
Type 1/ Type 2

All series in this

description

All construction in this description

Fire resistance rating: Class C

The Type 1 and/or Type 2 modules with the specified constructions in the table below, when installed

with an IEC listed mounting system that has been rated as a Class A System, is suitable to maintain the
System Class A Fire Rating.

The fire rating of the module is valid only when mounted in the manner specified in the mechanical

mounting instructions .

4.

Product Information

4.1 Unpacking and storage

At time of receipt, verify that the product delivered is in fact the product ordered. Carefully check the product

name and subname. Leave the product in its original packing box until you are ready to install.

Store packing boxes in a clean, dry area with relative humidity below 85% and ambient temperatures between -

20°C and 50°C.

Do NOT stack more than the maximum amount of allowable pallets on top of each other.

At the installation site, take care to keep modules and particular their electrical contacts clean and dry

before installation. If connector cables are left in damp conditions then the contacts may corrode. Any module
with corroded contacts should not be used.

Содержание MS M-36 Series

Страница 1: ...1 Installation Manual for Maysun Solar Monofacial PV modules For the latest version visit www maysunsolar com Version 2022 02...

Страница 2: ...Environmental Considerations 6 5 1 Climate conditions 6 5 2 Working environment 6 6 Site Selection 7 7 Mounting Instructions 7 7 1 Mounting methods 7 A Mounting with Bolts 7 B Mounting with Clamps 9 C...

Страница 3: ...l and should be installed and serviced by qualified personnel with knowledge of the mechanical and electrical requirements of the system The mechanical and electrical installation of the PV modules sh...

Страница 4: ...ment must be made in conformance with the grounding device manufacturer s instructions Common hardware items such as nuts bolts star washers lock washers and the like have not been evaluated for elect...

Страница 5: ...rank of the BOM concerned Module Fire Performance Type 1 Type 2 All series in this description All construction in this description Fire resistance rating Class C The Type 1 and or Type 2 modules with...

Страница 6: ...rical performance parameters of the module were measured under standard test conditions irradiance of 1000W m AM1 5 spectra ambient temperature of 25 C with a test uncertainty of 3 The maximum system...

Страница 7: ...nt orientations to different inverters or different MPPT if the inverter has more than one MPPT Refer to inverter manufacturers for further guidelines According to Intertek conducted IEC 61701 2011 sa...

Страница 8: ...8 www maysunsolar com...

Страница 9: ...t not deform the frame Be sure to avoid shadowing effects from the module clamps The module frame is not to be modified under any circumstances When choosing this type of clamp mounting method use at...

Страница 10: ...frame of each module has 4 7 10mm 0 28 0 39in mounting holes with specific location shown in Figure 3 Secure the module in each fixing location with an M6 bolt two flat washers a spring washer and nut...

Страница 11: ...nded in accordance with the appropriate respective National Electrical Code Proper grounding is achieved by bonding the module frame s and all metallic structural members together continuously using a...

Страница 12: ...uct Catalogue link for detailed grounding hole location and size at www maysunsolar com Method 1 Tyco grounding bolt 2058729 1 4 5 Figure 4 Tyco grounding bolt 2058729 1 1 Wire bolt and slot 3 Aluminu...

Страница 13: ...13 www maysunsolar com Figure 5 Tyco grounding bolt 1954381 2 Not applicable for the Maysun MOUNT module series 1 Wire slot available for 0 006 to 0 025in 2 Slider 3 Bolt 4 Base 5 Nut...

Страница 14: ...V resistant For MS 1500 V DC 90 C and are UV resistant All other cables used to connect the DC system should have a similar or better specification Maysun Solar recommend that all cables are run inapp...

Страница 15: ...es with an array string is typically 15A but the actual module specific rating can be found on the product label and in the product datasheet This fuse rating value also corresponds to the maximum rev...

Страница 16: ...ensure that the solar modules are clean before onset of summer Products installed at a tilt angle below 10 or which are located in particularly dusty areas are installed in landscape orientation or i...

Страница 17: ...e diodes even if they malfunction In a system using a battery blocking diodes are typically placed between the battery and the PV module output to prevent 10 Disclaimer Of Liability The installation h...

Отзывы: