background image

Installation and Operational Instructions for  
ROBA-stop

®

 Holding Brake Type 820.61_._ 

(B.1110.6.GB)

 

08/02/2010 K/GC/RJ/GF 

Chr. Mayr GmbH + Co. KG 

Tel.: 08341 / 804-0 

 

Eichenstraße 1 

Fax: 08341 / 804-421 

 

D-87665 Mauerstetten 

http://www.mayr.de 

Page 1 of 8 

Germany 

eMail: 

[email protected]

 

 

Please read these Installation Instructions carefully and follow them accordingly!

 

Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts.  

 
 

Contents: 

Page 1:  - Contents 

 

- Declaration of Conformity 

Page 2:  - Safety Regulations 

Page 3:  - Safety Regulations 

Page 4:  - Brake Illustrations 

 

- Parts List  

 

- State of Delivery 

 

- Function 

Page 5:  - Installation Conditions 

 

- Installation 

 

- Air Gap Adjustment 

 

- Braking Torque Adjustment 

Page 6:  - Brake Inspection 

 

- Replacing Worn Parts 

 

- Hand Release Installation 

 

- Hand Release Adjustment 

 

- Hand Release Parts List 

Page 7:  - Electrical Connection 

 

- Terminal Box Installation 

Page 8:  - Maintenance 

 

- Disposal 

 

- Malfunctions / Breakdowns 

 
 
 

Declaration of Conformity  

A conformity evaluation for the applicable EU directives has been carried out for this product.  
The conformity evaluation is set out in writing in a separate document and can be requested if required.  
It is forbidden to start use of the product until the machine or system into which it should be built is operating in accordance with all 
applicable EU directives. 
Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger of explosion.  
This statement is based on the ATEX directive. 

 
 
 

 

Please Observe! 
According to German notation, decimal points in this document are represented with a comma (e.g. 0,5 instead of 0.5). 
 

 
 

Содержание ROBA-stop 820.61 Series

Страница 1: ...t Page 6 Brake Inspection Replacing Worn Parts Hand Release Installation Hand Release Adjustment Hand Release Parts List Page 7 Electrical Connection Terminal Box Installation Page 8 Maintenance Dispo...

Страница 2: ...hich they are ordered and confirmed Using them for any other purpose is not allowed Guidelines for Electromagnetic Compatibility EMC In accordance with the EMC directives 89 336 EEC the individual com...

Страница 3: ...nt conditions or is installed in open air conditions unprotected from the weather Take precautions against freeze up of the friction surfaces in high humidity and at low temperatures Regulations Stand...

Страница 4: ...e check the state of delivery immediately mayr will take no responsibility for belatedly returned goods Please report transport damage immediately to the deliverer Please report incomplete delivery an...

Страница 5: ...must be present Observe the screw tightening torques according to Table 1 The shoulder screws 10 prevent the individual parts from falling apart They do not affect the brake function and should not be...

Страница 6: ...removed Please make sure that the helical springs 11 do not fall out Hand Release Installation The hand release can be installed onto every holding brake Type However due to the high spring forces mou...

Страница 7: ...ave rectifier 5 Bridge rectifier Parts List Terminal Box 37 Holding bracket 38 Cap screw M3 x 12 39 Terminal box lower part 40 O ring 41 Sealing plate 42 Hexagon nut M3 43 Cable clamp 44 Base plate 45...

Страница 8: ...ucts which have not been dismantled can be disposed of under the Code No 160214 Mixed Materials or Components under Code No 160216 or the objects can be disposed of by a certified waste disposal firm...