MAYAH C11 Series Скачать руководство пользователя страница 1

© 2010 MAYAH Communications

Manual for C11

Содержание C11 Series

Страница 1: ...2010 MAYAH Communications Manual for C11...

Страница 2: ...arks All other trademarks are acknowledged with this C11 User Manual Order No C11 UM001 Revision 02 2010 2010 MAYAH Communications For copying this manual even by extract an explicit written permissio...

Страница 3: ...o access C11 via FTP 18 How to start Web Remote 18 How to update C11 firmware 19 How to activate Keycodes 20 How to reset C11 20 Boot Script Part III Front panel user interface 22 22 1 Monitor 24 Head...

Страница 4: ...Storage 66 Card menu 67 4 System 67 Configurations 68 Miscellaneous 68 Device ID 68 Date Time 69 LCD Display 69 System health 69 Versions 69 Connections 70 User Interface 70 Display option 70 Factory...

Страница 5: ...Part I Introduction...

Страница 6: ...tween two kinds of C11 models standard models C1130 31 35 C1140 41 C1180 81 advanced models C1150 51 55 C1160 61 C1190 91 The advanced models have got the following additional features Slots for optio...

Страница 7: ...files The audio can be monitored via the headphones and the line output see also chapter First Start Connectors e Recording during Transmission depending on model C11 can also record the transmitted a...

Страница 8: ...ntrol via terminal emulation see also Chapter System Miscellaneous Ancillary Data Special MAYAH C11 rack mount accessories Mechanical Kit to mount two 19 C11xx units side by side in a 19 rack order no...

Страница 9: ...Part II First Start...

Страница 10: ...dvanced models Installation in rack When installing the C11 in a rack or another assembly you should make sure that the housing has the necessary air exchange and if one C11 mounted on top of the othe...

Страница 11: ...udio In Analog output 2 balanced XLR AES EBU In Out Sync In DE9 9 pin Sub D female see chapter Useful Accessories for Adapter Order No or consult the technical manuals at www mayah com support support...

Страница 12: ...phone lines PC Memory card e g Compact Flash card with PC card adapter for recording or config backup SD card slot for recording recommended or configuration backup d USB ports C11 has got two USB por...

Страница 13: ...r contact MAYAH communications for pin layout f Power supply connector Special Hirose HR10 port for C11 AC DC power supply or MAYAH RPSU12 Use only an original MAYAH C11 power supply MAYAH is not liab...

Страница 14: ...button Alphanumeric keypad a Function buttons The buttons F1 F4 have got a context sensitive meaning i e in different situations different functionalities are assigned Which functionality is currentl...

Страница 15: ...g H h I i Assigned key 5 5 J j K k L l Assigned key 6 6 M m N n O o Assigned key 7 7 P p Q q R r S s Assigned key 8 8 T t U u V v Assigned key 9 9 W w X x Y y Z z Assigned key 0 0 SPACE Assigned key...

Страница 16: ...tch on C11 To prevent accidental switch off this must be done either via front panel menu item System Switch off or by holding the F4 button for approx 2 seconds to open the Switch Off dialog b Hard s...

Страница 17: ...ing digits of the IP address of your C11 and your PC must be the same Example Net mask 255 255 255 0 11111111 11111111 11111111 00000000 PC IP address 192 168 1 56 C11 with IP address 192 168 1 57 is...

Страница 18: ...ava 6 applets must be available within the web browser The Web Remote access data are by default Host IP address of C11 Username WebAdmin Password WebPower Additional password protection is used for t...

Страница 19: ...es at the LCD screen and or blinking of LEDs After this step is completed successfully another reboot will occur automatically 3 First start of the new firmware At this point some further update proce...

Страница 20: ...d sys_reset factory in the Boot Script file and apply the boot script as described in the next chapter of this manual 2 7 7 Boot Script This feature should only be used by expert users for emergency s...

Страница 21: ...Part III Front panel user interface...

Страница 22: ...the user can select following functionalities of C11 with the function keys F1 F2 and F3 Monitor menu F1 Codec F2 Play record menu F3 advanced models only see technical specification Furthermore the...

Страница 23: ...vel Meters Upper levels display Send Level Left Right transmit level to the connection partner Bottom levels display Receive Level Left Right receive level from the connection partner Status displays...

Страница 24: ...of the framing state indicator means that C11 is currently connecting connection in progress 3 1 1 Headphones Here the audio source and the volume for the headphone output on the front panel can be se...

Страница 25: ...he and cursor buttons In the rotary knobs field adjustable levels and pannings can be selected with the and cursor buttons The currently adjustable level or panning is underlined With the and cursor b...

Страница 26: ...ofile can be renamed Del Clears all the settings in the currently selected mixer profile i e loading such a profile has no effect 3 1 2 2 2 Factory profiles With the current firmware version 4 factory...

Страница 27: ...plied to particular Enhanced Application modes e g to Dual Mode or Intercom They are loaded automatically when one of the corresponding Enhanced Application modes is activated See also chapter Codec S...

Страница 28: ...ereas panning s are shown in the bottom row Possible inputs for Out are Audio inputs Decoder level left and right Decoder level is the level of received audio from the remote side of connection Playba...

Страница 29: ...Audio inputs Playback level left and right This is the level of played files Note When any of the Enhanced Application modes are activated the Rec Play captions are renamed according to the applicatio...

Страница 30: ...miter guarantees that too high audio input levels are not just cut off which caused big distortions but softly clipped b aes digital AES EBU c mic analog mic level advanced models only Limiter The lim...

Страница 31: ...Just available for microphone input This feature prevents that low frequencies at audio input damages audio equipment 48 V Just available for microphone input 48 V phantom power enables to use C11 wi...

Страница 32: ...left received mono signal is provided to the left audio output right received mono signal is provided to the right output c REC only advanced models if mono format e g Linear 16bit Mono is chosen for...

Страница 33: ...In signal b AES Master This item activates or deactivates the AES Master mode On default C11 acts as the clock generator for AES audio interface Off digital audio will be clocked via the AES EBU input...

Страница 34: ...interfaces and codec settings except audio inputs and levels Sub menu items when no connections are established Connect menu F1 Status menu F2 Setup menu F3 Sub menu items when a connection is establ...

Страница 35: ...hen the repeating connection will be established over the same network and with the current codec quality settings 3 2 1 2 Phone book menu At the phone book screen up to 256 predefined phone book entr...

Страница 36: ...are explained in the MAYAH Application Note 9 Part 1 2 If an existing phone book entry is edited or a new one is created it should be considered that some communication interfaces do not support all...

Страница 37: ...can be entered At SIP protocol also alphanumeric SIP addresses are possible Note To send or receive a multicast stream just enter the multicast address here Multicast connection usually cannot be a bi...

Страница 38: ...and providers d POTS advanced models only At number the phone number of the other side codec can be entered e WLAN advanced models only future option protocol here IP protocol can be set to RTP SIP di...

Страница 39: ...SIP RTP connection time if not connected 0 connection quality best good sufficient bad local IP address remote IP addr IP or SIP address of connection partner input bit rate in kbps output bit rate i...

Страница 40: ...available if connection partner is a MAYAH codec c 3G UMTS optional advanced models only current protocol SIP RTP connection type 3G UMTS HSDPA HSUPA GSM GSM GPRS EDGE NOTE How detailed the connection...

Страница 41: ...WLAN future option advanced models only current protocol SIP RTP connection time if not connected 0 connection quality best good sufficient bad signal strength graphic text 3 bars best 2 bars good 1 b...

Страница 42: ...ate Bit rate Mode Note Parameters shown in this screen cannot be modified 3 2 3 Setup menu In the setup menu the following configurations can be done Settings of all communication interfaces INTERF F1...

Страница 43: ...el controls since the device can become inaccessible via IP in case of the network conditions change b Address sets the IP address for the appropriate interface e g 192 168 10 50 if DHCP is deactivate...

Страница 44: ...ess Translation The public IP address is necessary since the SIP device on the other end needs this info to find the local client In this field an IP address or a URL can be entered This setting is op...

Страница 45: ...he following access data Name Password Phone Number not always necessary Account Phonenr Here the phone number of the registration access data can be entered This parameter is not always necessary Acc...

Страница 46: ...Note 2 At D channel protocols NI1 and 5ESS an ID must be assigned for every B channel Often the last 4 digits of the ISDN number must be entered as ID number Note 3 MSN ID cannot be longer than the l...

Страница 47: ...for external access e g 9 PBX digits determines the number of digits BEFORE the additional preceding PBX number becomes valid For example PBX 9 PBX digits 5 Entered number 1234 Dialed number 1234 Ente...

Страница 48: ...r PCM with 13 segments law as used in USA and Japan also non linear PCM but 15 segments Note If G 711 law is not set properly then strong disturbances occurs at G 711 transmissions G 711 level Sometim...

Страница 49: ...er 1234 Dialed number 1234 Entered number 01234 Dialed number 901234 b Predial Sometimes it is necessary to use a special provider to guarantee the quality of the service or the carriage of telephone...

Страница 50: ...IN number of your SIM card must be entered Check if the PIN is entered correctly before insert the 3G UMTS card C11 provides the PIN to the SIM card automatically Three false attempts will block the S...

Страница 51: ...cy range can be set Europe default U S f User 3G user identification g Password User confirmation by password h Delay sets the size of the receive buffer in ms Max possible value 5 000 ms Note RTP pac...

Страница 52: ...able and can be loaded G 711 A law usually used in Europe G 711 law usually used in America and Japan G 722 4SB Mono optional C1140 41 C1160 61 only Algorithm 4SB ADPCM Sample rate 32 kHz Bit rate 128...

Страница 53: ...Algorithm AptX no sync Sample rate 32 kHz Bit rate 256 kbps Mode Dual Mono Note This profile can be used to connect to older Apt X devices via ISDN with 128 kbps 1 ISDN Line 2 B Channels for mono conn...

Страница 54: ...192 kbps Mode Joint stereo AAC Mono Algorithm AAC MPEG 4 Sample rate 48 kHz Bit rate 64 kbps Mode Mono AAC Stereo Algorithm AAC MPEG 4 Sample rate 48 kHz Bit rate 128 kbps Mode Stereo AAC HE 24 Param...

Страница 55: ...automatic codec recognition system FlashCast No connection to devices with different settings is possible while these profiles are active To re enable automatic codec recognition after using these pro...

Страница 56: ...d for future use in the menu MONITOR MIXER MEM SKINS 3 2 3 3 1 Intercom In Intercom Mode besides the main connection a command connection e g to call for technician can be established additionally Thi...

Страница 57: ...Example English reporter at the analog input L MSN of first B channel 33 Spanish reporter at the analog input R MSN of second B channel 34 Call 44 12345 33 to listen to the English voice call 44 1234...

Страница 58: ...irect menu will show a primary destination and a redundancy destination fields These fields have to be filled in with the primary and the redundancy destination IP addresses Attention should be paid t...

Страница 59: ...sting files can be played back from supported storage media The play record menu supports the following Playback and FTP upload of MPEG and Linear coded files format wave or broadcast wave which are s...

Страница 60: ...ress Current playback position is shown as on the progress bar c Markers Markers can be set by pressing OK button during playback Markers are displayed as thin vertical lines on the progress bar To ju...

Страница 61: ...F3 Meaning of the control buttons Upload Starts the transfer of the selected track s according to the settings configured at params All Selects all tracks of the storage media Params Params Parameters...

Страница 62: ...d F2 USB USB storage media F3 PC Card e g Compact Flash card with PCMCIA Adapter Following actions can be done with the selected track Pressing OK button or cursor button will activate the PLAY PAUSE...

Страница 63: ...n F2 Stops record n shown F3 Setup menu Note Pause record means that pressing F1 button continues recording on the same track file Stop record means that recording on the selected track is stopped and...

Страница 64: ...recording L2 Mono Algorithm MPEG L 2 Sample rate 24 kHz Bit rate 64 kbps Mode Mono L2 Joint Stereo Algorithm MPEG L2 Sample rate 32 kHz Bit rate 128 kbps Mode Joint stereo L2 Stereo Algorithm MPEG L2...

Страница 65: ...ayers Algorithm AAC HE Sample rate 32 kHz Bit rate 24 kbps Mode Parametric stereo AAC HE 64 Stereo raw format may be not compatible with other players Algorithm AAC HE Sample rate 44 1 kHz Bit rate 64...

Страница 66: ...currently selected storage medium size and available space is displayed on the right side If multiple storage devices are available the desired medium can be selected with the cursor button For every...

Страница 67: ...saved A configuration can be selected with the cursor buttons and Following features are available a Use Use executes the currently selected configuration To prevent misuse the user will be asked if...

Страница 68: ...s The currently chosen item is highlighted The miscellaneous start screen looks like 3 4 2 1 Device ID This screen enables to edit the name of C11 max 128 characters Furthermore the serial number can...

Страница 69: ...ature in C Note E g an operational temperature between 50 and 65 C is quite normal for C11 at 20 22 C environment temperature depending on system load Note 2 Alarm LED will light up if device is overh...

Страница 70: ...7 User Interface Here can be set if C11 runs in either Expert Mode default User Mode few menus are disabled 3 4 2 8 Display option This screen enables to set file playback time display to elapsed time...

Страница 71: ...ted by the network e g faulty switch and new remote control attempts are blocked by C11 since it is convinced it is still remote controlled but it isn t 3 4 2 11 AJC The feature AJC Automatic Jitter C...

Страница 72: ...art up When adapter is active a blue LED lights up on its body The following ancillary data parameters can be set Baudrate Baud rates from 1 200 to 115 200 Databits 5 6 7 8 Parity None Even Odd Defini...

Страница 73: ...vent accidental switch off this must be done via this menu item This dialog also opens if F4 button is pressed longer than 2 seconds Switch OFF dialog looks like this Since cancel is the default selec...

Страница 74: ......

Страница 75: ...Part IV How to use for...

Страница 76: ...n Establishing connections can be done via Codec Connect c Start Recording After transmission is established the following steps must be done Select the storage media at menu item Rec Rec Setup Storag...

Страница 77: ...ser profile may be saved b Establish connection Establishing connections can be done via Codec Connect c Start Playback After transmission is established the following steps must be done Select the ri...

Страница 78: ......

Страница 79: ...Part V Technical specifications...

Страница 80: ...4 Ethernet Black C1135 2 Ethernet Black Advanced IP models C1150 4 Ethernet White C1151 4 Ethernet White C1155 2 Ethernet White Standard ISDN models C1140 4 Ethernet ISDN Grey C1141 4 Ethernet ISDN G...

Страница 81: ...6 20 24 bit 32 48 kHz Std APT X 16 bit 32 48 kHz Enh APT X 16 20 24 bit 32 48 kHz File formats Linear PCM wav 16 bit 32 48 kHz Mono Stereo MPEG L2 Musifile msf 64 256 kbps 24 48 kHz Mono Joint Stereo...

Страница 82: ...on sessions FTP File transfer update HTTP Web Browser Remote Control Telnet Remote Control SNMP Remote Control Monitoring Power Supply 12 14V DC Hirose connector PSU Power Supply Unit external 100 240...

Страница 83: ...Audio settings setup 29 Auto restore 69 Automatic Jitter Compensation 71 B Backlight 69 Backspace 14 15 Baud rate 72 Before start 10 Bootscript 20 Buttons 14 BWF 63 C Cell Technology 50 CF card 8 65 6...

Страница 84: ...buttons 14 G G 711 law 45 G 711 level 45 G 711 service 45 G 722 timeout 70 Gain adjustment 27 Gateway 43 Global Proxy 43 GPIO 10 GPIO signals transmission 72 Graphic user interface 15 H Handshake 72...

Страница 85: ...s 25 Mixer Rec 28 Mixer Send 28 Mixer skin profiles 27 Mixer user profiles 26 Models 80 MSN Multiple Subsciber Number 45 Multicast 36 Mute 29 N Netmask 43 NI1 45 O Optional algorithms 19 Opto In 10 P...

Страница 86: ...s indication 13 Status menu 39 Stop bit 72 Storage device 65 STUN 43 Switch off 73 Switching on and off 16 System health 69 System reset 20 70 System settings 68 T Technical specification 80 81 Temper...

Страница 87: ...MAYAH Communications GmbH Am Soeldnermoos 17 85399 Hallbergmoos Germany Tel 49 0 811 5517 0 Fax 49 0 811 5517 55 info mayah com www mayah com...