MAXXAIR
®
SKYMAXX ROOFLIGHT
INSTALLATION INSTRUCTIONS, INFORMATION AND
OPERATING GUIDE
FOR MAXXAIR SKYMAXX ROOFLIGHT 97500i & 97510i
READ AND SAVE THESE INSTRUCTIONS
NOTE:
Refer to Installation Instructions, Information and Operation Guides regarding the model you have
purchased.
The
SKYMAXX ROOFLIGHT
installs into a standard caravan roof opening of 400 mm x 400 mm
(15.75 in. x 15.75 in.).
To determine if your roof opening is correctly sized, simply remove the interior ceiling garnish trim ring of
your existing roof vent and measure the ceiling opening or verify the opening is large enough by sliding
the Rooflight interior ceiling flange into the opening.
The Rooflight is designed for a minimum roof thickness 23 mm to 60 mm maximum (0.90 inches to 2.36
inches).
The LED lighted Rooflight requires a minimum 12 Volt DC, 2 amp service. Confirm that the circuit you
intend to use will accommodate the additional load. Circuit must be fused and use appropriate gauge
stranded wire for electrical connections
.
NOTE: Wall Control for LED lights must be provided by installer.
NOTE: THE ROOFLIGHT MUST BE CLOSED PRIOR TO TRANSPORTING OR MOVING THE CARAVAN.
WARNING!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by AIRXCEL, INC. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
CAUTION!
FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS
OR EXPLOSIVE MATERIALS OR VAPORS.
P/N: 11-90014i 01-2019