PLATFORM WILL NOT RAISE
1.
Verify that power is being supplied to the Solenoid Terminal “A”. Recharge
the battery if less than 12 volts.
2.
Fill Reservoir to within 1/2” below the top with the recommended hydraulic
fluid.
3.
Touch a jumper wire to terminals “A” & “C”. If motor runs, check Switch,
Switch connections, and White wire. Correct the connections or replace
the Switch.
4.
Touch heavy jumper cables to terminals “A” & “B”.
a. If motor runs, replace the motor solenoid.
b. If motor does not run, repair or replace the pump motor.
5.
Check for structural damage. Replace worn parts.
6.
Check filter in the pump Reservoir. Replace if necessary.
7.
Check for a broken motor-to-pump coupler. Replace if necessary. A worn
pump is extremely noisy, and needs replacement.
8.
If equipped with a Low Voltage Thermal Switch (LVTS), system could shut
down if the motor temperature or battery voltage level reach an unaccept-
able level. Read decal P/N 264776 located near the switch to determine
what steps need to be taken to correct the problem.
Terminal “A”
Terminal “B”
Terminal
“C”