Maxon PARVALUX SC 50/15 Скачать руководство пользователя страница 1

SC 50/15 Controller 

Hardware Reference

Содержание PARVALUX SC 50/15

Страница 1: ...SC 50 15 Controller Hardware Reference ...

Страница 2: ...personnel Prior commencing with any activities You must carefully read and understand this manual and You must follow the instructions given therein The SC 50 15 Servo Controller is considered as partly completed ma chinery according to EU Directive 2006 42 EC Article 2 Clause g and is intended to be incorporated into or assembled with other machinery or other partly completed machinery or equipme...

Страница 3: ...ely lock any power engaging equipment against unintentional engagement and tag it with your name Requirements Make sure that all associated devices and components are installed according to local regulations Be aware that by principle an electronic apparatus cannot be considered fail safe Therefore you must make sure that any machine apparatus has been fitted with independent monitoring and safety...

Страница 4: ... Temperature Extended range a C 30 84 Derating 0 278 A C Figure 2 2 3 Temperature Storage C 30 85 4 Altitude b m 0 6000 MSL 5 Humidity 5 90 condensation not permitted a Operation within the extended range is permitted However a respective derating declination of output current Icont as to the stated values will apply b Operating altitude in meters above Mean Sea Level MSL Table 2 4 Technical data ...

Страница 5: ...d motor connector X1 pin assignment for BLDC motor Power supply requirements 1 Output voltage Vcc 12 50 VDC 2 Absolute output voltage Min 10 VDC max 56 VDC 3 Output current Depending on load Continuous max 15 A Short time acceleration 10 s max 30 A Table 3 11 Power supply requirements Parvalux Electric Motors Ltd SC 50 15 Controller Hardware Reference Vcc 1 V UN no 1 0 98 n M n M Setup 08 07 Setup...

Страница 6: ...ss section 0 25 0 75 mm2 with cable ferrule without plastic sleeve Stripping length 8 0 9 0 mm Recommended tools Slotted head screwdriver size 0 4 x 2 5 mm Table 3 15 I O connector X3 specifications X3 pin Signal Description 1 DigIN1 Digital input Enable 2 DigIN2 Digital input Direction 3 DigIN3 Digital input Stop 4 DigOUT1 DIgital output Ready 5 Vsensor Sensor supply voltage 5 VDC IL 100 mA 6 AnI...

Страница 7: ...a PWM signal with fixed frequency and amplitude can be used to adjust the speed set value The desired change in the set value is achieved by variation of the duty cycle in the range 0 100 Both the amplitude and the duty cycle have an influence on the resulting speed The mean value of the applied PWM voltage corresponds to the analog input signal Speed Set Value The specified upper limit frequency ...

Страница 8: ...en loop speed control with IxR compensation 3 Speed set value score Analog input Speed Set Value Potentiometer 1 4 Speed sensor and encoder resolution See table 3 28 See table 3 28 5 6 7 Hall sensor polarity Standard See note on page 14 Inverted See note on page 14 8 Speed range Speed range See table 3 29 Table 3 27 DIP switch settings functionality Important DIP switch settings during closed loop...

Страница 9: ...ic Motors Ltd SC 50 15 Controller Hardware Reference Setup 16 15 Setup Setup Setup 3 0 3 0 Figure 3 19 LEDs location 3 6 3 7 Status indicators The SC 50 15 features a set of LED indicators to display the device status Wiring LEDs Green LED shows the operating status Red LED indicates errors OFF ON OFF 1s 1x 2x 3x 4x 5x Ground safety earth connection optional SC 50 15 Power supply X1 X2 I Os 12 50 ...

Страница 10: ...et the Speed Set Value the potentiometer P1 will adjust the speed ramp in the range of 5 s 20 ms in linear fashion 3 Adjust the potentiometer P2 to the required limiting values of Icont in the range of 1 15 A and Imax in the range of 2 30 A Both ranges are adjusted at the same time the limiting values change in linear fashion Important The limiting value Icont should be below the motor s nominal c...

Страница 11: ...g license 06 operation modes 17 P part numbers 594385 04 performance data 04 precautions 03 prerequisites prior installation 06 prohibitive signs 02 protective measures ESD 03 purpose of the device 03 purpose of the document 02 R regulations applicable 04 S safety alerts 02 safety first 03 signs used 02 single ended encoder 12 speed control settings 17 standards fulfilled 05 status LEDs 15 supply ...