Electrical Installation
Connections
IDX 56 User Manual
mmag | 2020-04 | rel9398
4-35
4.3.5.1
Power Supply VV
CC
Table 4-27
Power supply requirements
1)
Use the formula below to calculate the required voltage under load.
2)
Choose a power supply according to the calculated voltage. Thereby consider:
a)
During braking of the load, the power supply must be capable of buffering the recovered
kinetic energy (for example, in a capacitor).
b)
If you are using an electronically stabilized power supply, make sure that the overcurrent pro-
tection circuit is configured inoperative within the operating range.
The formula already takes the following into account:
• Maximum PWM duty cycle of 90%
• Controller’s max. voltage drop of 1 V @ 12 A
KNOWN VALUES:
•
Operating torque M [mNm]
•
Operating speed n [rpm]
•
Nominal motor voltage U
N
[Volt]
•
Motor no-load speed at U
N
; n
O
[rpm]
•
Speed/torque gradient of the motor
Δ
n/
Δ
M [rpm/mNm]
SOUGHT VALUE:
•
Supply vV
CC
[Volt]
SOLUTION:
Continued on next page.
Power supply requirements
Output voltage
+V
CC
12…48 VDC
Absolute output voltage
min. 10 VDC; max. 60 VDC
Output current
Depending on load
• continuous max. 12 A
• short-time (acceleration, <10 s) max. 24 A
V
CC
U
N
n
O
-------
n
Δ
n
Δ
M
---------
M
⋅
+
1
0.9
-------
⋅
⋅
1
V
[ ]
+
≥
Содержание IDX 56
Страница 1: ...IDX 56 Drives User Manual mmag Edition 2020 04 DocID rel9398 User Manual...
Страница 4: ...Table of Contents IDX 56 User Manual A 4 mmag 2020 04 rel9398 page inte ntionally left blank...
Страница 12: ...About About the Safety Precautions IDX 56 User Manual 1 12 mmag 2020 04 rel9398 page inte ntionally left blank...
Страница 20: ...Specifications Standards IDX 56 User Manual 2 20 mmag 2020 04 rel9398 page inte ntionally left blank...
Страница 53: ...IDX 56 User Manual mmag 2020 04 rel9398 Z 53 Index p age intention ally left blank...