background image

 

Safety 

 

2.7  Responsibilities of operating company and requirements for 

operator 

The operating company must comply with occupational safety regulations. The operating 

company is responsible for providing personal protective equipment such as protective 

footwear and protective clothing for operators and maintenance personnel. Valid accident 

prevention regulations, legal and operational guidelines, occupational safety regulations, 

and environmental regulations must be observed. 

The operating company is responsible for annual inspections and the technologically 

fault-free condition of the liftgate. An annual inspection must be carried out by qualified 

personnel and the results of this inspection must be entered in the inspection record 

book. 

Any defects must be corrected and missing parts replaced immediately. 

The operating company is responsible for the prompt repair of known defects. 

IMPORTANT

 

Additional regulations are printed in the inspection record book. The inspection record 

book is part of this user manual. 

IMPORTANT

 

The inspection report dealing with the static and dynamic inspection performed before 

commissioning the liftgate is kept in the inspection record book. 

 

The liftgate must be operated in accordance with the user manual. The liftgate may be 

operated, maintained, and serviced only by personnel who have received appropriate 

training and have been specifically instructed in the dangers associated with its 

operation. 

Only persons aged 18 years or older who have been instructed in the operation and 

maintenance of the liftgate and have proven their capability to the company are allowed 

to independently operate and maintain the liftgate. They must be expressly assigned to 

its operation and maintenance. The assignment for operating and maintaining the liftgate 

must be issued in writing. 

If more than one person is working on the liftgate, the operating company must appoint a 

supervisor. 

Liftgate maintenance may be performed by specially trained personnel only. 

 

WARNING 

 

Incorrect or improper use or handling of the liftgate or, for example, errors caused by its 

being operated by unqualified personnel can create risks for operators and bystanders 

that may result in serious or fatal injuries. 
The liftgate may be operated only by qualified personnel. 

 

Содержание GPC X1-LD

Страница 1: ...GPC X1 LD liftgate GPC X1 LDF liftgate User Manual LIFT CORP 11921 Slauson Avenue Santa Fe Springs CA 90670 2221 P 800 227 4116 562 464 0099 F 888 771 7713 Date 08 2020 Part No 20 912 419...

Страница 2: ...information MAXON LIFT CORP Corporate Office 11921 Slauson Avenue Santa Fe Springs CA 90670 2221 P 800 227 4116 562 464 0099 F 888 771 7713 Customer Service Parts USA Canada Mexico P 800 227 4116 F 88...

Страница 3: ...r operator 9 2 8 Commissioning 10 2 9 Handling and behavior during operation 13 2 10 Danger notice sticker Safe handling of the liftgate 16 2 11 Permissible loads 17 2 12 Load diagram 18 Operation of...

Страница 4: ...switched off 35 5 6 Emergency Platform moved by mechanical means 36 5 7 Malfunction 36 Decommissioning disassembly and disposal 37 Electrical circuit diagram 40 Hydraulic circuit diagram 41 Warranty l...

Страница 5: ...liftgate Do not deviate from the instructions contained in this manual By doing so you risk injury damage to property and voiding of the warranty Make sure that this manual always remains with the li...

Страница 6: ...flipped open 1 Platform 2 Warning flags 3 License plate light 4 License plate holder 5 Lifting cylinder 6 Support arm 7 Step 8 Lifting arm 9 Closing arm 10 Compact power unit 11 Closing cylinder 12 A...

Страница 7: ...ridge plate 1 Platform 2 Warning flags 3 License plate light 4 License plate holder 5 Lifting cylinder 6 Lifting arm 7 Closing arm 8 Foot control 9 Compact power unit 10 Closing cylinder 11 Axle assem...

Страница 8: ...cally locked out electrically Hydraulics The liftgate is driven by a compact power pack mounted on the supporting structure directly on the closing cylinder It serves to move the lifting or closing cy...

Страница 9: ...ber and the rating plate The liftgate serial number is the liftgate s most important ID number It is required for all technical support spare parts orders and warranty claims and is found on every dev...

Страница 10: ...minor or moderate injury NOTICE Failure to heed this notice can result in damage to property or the environment And IMPORTANT Important information or useful tip for correct use 2 2 Safety The Safety...

Страница 11: ...hoses Danger from pressurized liquids and gases Hydraulic components lines can burst and cause injury Inspect hydraulic components lines at regular intervals maintenance schedule Install only state of...

Страница 12: ...valve may be adjusted only by a qualified specialist using a test weight and a manometer Fuses Defective fuses may only be replaced by fuses that correspond to the values specified in the circuit dia...

Страница 13: ...spection report dealing with the static and dynamic inspection performed before commissioning the liftgate is kept in the inspection record book The liftgate must be operated in accordance with the us...

Страница 14: ...ts on the liftgate Watch out for potential crushing points Define and observe the danger zone including for third parties 6 Check that supports are correct positioned on a suitable surface before comm...

Страница 15: ...purpose 10 Liftgates operated in areas of vehicle traffic or where the liftgate extends into these areas must be suitably protected against danger from vehicles 11 During operation the liftgate platfo...

Страница 16: ...ing notice stickers on the vehicle or the absence of a load diagram missing rating plate may make it more difficult to recognize hazards and result in injuries Regularly check the condition of warning...

Страница 17: ...lowered including platform tip 4 Do not unnecessarily stand within the liftgate s range of movement 5 Do not stand under the lifting device and load 6 Do not stand on the lifting device except for ope...

Страница 18: ...a safe distance during operation when using the handheld control on page 22 13 Do not deliberately cause the lifting device to vibrate 14 Do not throw objects onto or from the lifting device 15 Place...

Страница 19: ...IMPORTANT Dirt can impair the functioning of cart stops The operating company must keep these safety devices clean at all times 20 When transferring loads from vehicle to vehicle only one of the two p...

Страница 20: ...dicate potential incorrect and correct usage of the liftgate This sticker is supplied with all new liftgates The installing company must place it in a clearly visible location on the inside of the veh...

Страница 21: ...built in protection against loads that exceed the rated capacity or that are not within the correct loading distance and are moved from the vehicle to the platform Overloading of this type can for exa...

Страница 22: ...When the platform is completely lowered it may be traversed loaded only with loads that do not exceed its rated capacity Operate the lifting and lowering functions only with the platform in the horizo...

Страница 23: ...operate 3 2 Operation using the control panel membrane switch From the control panel all functions are initiated by pressing two different pushbuttons simultaneously The diagram shows which buttons a...

Страница 24: ...be operated one after the other WARNING Be careful not to confuse the control elements for tilt up tilt down and lift lower Incorrect operation could injure third parties Define and observe the danger...

Страница 25: ...onfuse the control elements for tilt up tilt down and lift lower Incorrect operation could injure third parties Define and observe the danger zone including for third parties WARNING Crushing or shear...

Страница 26: ...unctions only while standing in the positions shown in the illustration Operating position on the platform or vehicle floor The operator must stand a minimum of 10 inches from the front edge of the pl...

Страница 27: ...During loading and unloading of the platform the GPC X1 LD bridge plate and both of the GPC X1 LDF bridge plates must be folded open position with the platform completely lowered After use the bridge...

Страница 28: ...side of the liftgate platform manually 6 Open the left vehicle door 5 Lower the liftgate platform using the control panel Lower or if you re standing on the platform using the foot controls or the opt...

Страница 29: ...rols or the optional 3 button handheld control Tilt up Tilt down Lower Loading and unloading the liftgate 10 The liftgate platform is now ready for loading and unloading Loading the vehicle 11 Tilt up...

Страница 30: ...Lower or if you re standing on the platform using the foot controls or the optional handheld control Lower so that you can close the left vehicle door 16 Close the left vehicle door 17 Fold up the rig...

Страница 31: ...r tilt up tilt down or lift lower Incorrect operation could injure third parties Define and observe the danger zone including for third parties 20 Close the right vehicle door 19 Close the liftgate pl...

Страница 32: ...nections are tight Check that cables and hoses are able to move freely Correct shearing and chafing points on cables and hoses Immediately replace damaged hydraulic hoses with new hoses of the same qu...

Страница 33: ...gloves when handling hydraulic fluid Handle and dispose of hydraulic fluid in accordance with local regulations IMPORTANT Repairs to load bearing components are to be carried out only by an authorized...

Страница 34: ...nexpected movement that results in injury WARNING Replace electrical system components only with approved original electrical components with EMC approval External influences on electrical equipment m...

Страница 35: ...e drops to 12 volts the current doubles to 300 amperes WARNING This high current accompanied by a low voltage causes the copper winding to overheat As a result the protective coating on the copper win...

Страница 36: ...ftgate activated LED on Power supply is functioning correctly Platform position 0 to approx 60 LED off Tilt sensor S1 in switching position is functioning correctly Corner lights are activated Platfor...

Страница 37: ...panel control cabinet to power pack is defective Control lines in power pack are defective Control panel control cabinet is defective 3 Liftgate does not open or opens slowly Platform sticks at the ve...

Страница 38: ...weight Load is not within the loading distance Load is too heavy Safety valve is incorrectly set Pump is defective Voltage is too low 10 Platform does not tilt up from ground when unloaded Control pa...

Страница 39: ...attery main switch to stop the motor from running Then take the liftgate to the nearest authorized repair shop or call our customer service so that the defect can be corrected WARNING Electrical hazar...

Страница 40: ...NT If the liftgate breaks down in this way contact customer service or an authorized repair shop for more information DANGER Danger Serious risk of death or injury When the liftgate is unsecured and t...

Страница 41: ...e opened only with the aid of a crane or forklift When disposing of the liftgate the hydraulic system lifting and closing cylinders reservoir hydraulic pump solenoid valves cables high pressure hoses...

Страница 42: ...nsioned springs Use only trained and qualified maintenance personnel WARNING Risk of injury during disassembly assembly particularly of safety devices e g removing solenoid valves due to improper or i...

Страница 43: ...er disposing of packing materials store all parts in a secured manner and carefully remove transport locks WARNING When transport locks are removed parts may fall If parts fall fluid can escape Carefu...

Страница 44: ...Electrical circuit diagram 40 Electrical circuit diagram...

Страница 45: ...Hydraulic circuit diagram 41 Hydraulic circuit diagram...

Страница 46: ...MAXON Part Number s 6 MAXON R M A and or Authorization if applicable see below 7 Person contacted at MAXON if applicable 9 2 Purchase Part Warranty Term of Warranty 1 Year from Date of Purchase Type...

Страница 47: ...diagnosis of problem Warranty and Technical Information is available by calling Maxon s Customer Service Department NOTE Check with Customer Service Department for updated versions of Manuals on an a...

Страница 48: ...Notes 44 Notes...

Страница 49: ...45...

Страница 50: ...46...

Отзывы:

Похожие инструкции для GPC X1-LD