Motherboard Design Guide
Requirements for Components of Third-party Suppliers
ESCON Module 50/8 Hardware Reference
CCMC | 2021-08 | rel10243
5-39
An additional choke must feature electromagnetic shielding, a high saturation current, minimal losses, and a
nominal current greater than the continuous current of the motor. The below wiring examples refer to addi-
tional inductances of 4.7
μ
H and 22
μ
H. If a different additional inductance is required, also the filter compo-
nents must be adapted accordingly. Should you need further help with the filter design, contact maxon Sup-
port at
http://support.maxongroup.com.
Example 1
Example 2
Figure 5-26
Wiring of Motor Winding 1 (analogously valid also for Motor Windings 2 & 3)