![Maxon EPOS 50/5 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/maxon/epos-50-5/epos-50-5_hardware-reference-manual_1745151049.webp)
Setup
Connections
EPOS4 50/5 Hardware Reference
CCMC | 2022-04 | rel10445
3-49
3.3.11
CAN 1 (X11) & CAN 2 (X12)
The EPOS4 is specially designed being commanded and controlled via a Controller Area Network (CAN), a
highly efficient data bus very common in all fields of automation and motion control. It is preferably used as
a slave node in the CANopen network.
For the CAN configuration
“DIP Switch Configuration (SW1)” on page 3-56.
Figure 3-39
CAN 1 connector X11/CAN 2 connector X12
Table 3-54
CAN 1 connector X11/CAN 2 connector X12 – Pin assignment
Table 3-55
CAN-COM Cable
Continued on next page.
X11
X12
Head A
Prefab
Cable
520857
Head B
520858
Head B
Signal
Description
Pin
Color
Pin
Pin
1
white
7
1
CAN high
CAN high bus line
2
brown
2
2
CAN low
CAN low bus line
3
green
3
3
GND
Ground
4
Shield
5
4
Shield
Cable shield
CAN-COM Cable (520857)
Cross-section
2 x 2 x 0.14 mm
2
, twisted pair, shielded
Length
3 m
Head A
Plug
Molex CLIK-Mate, single row, 4 poles (502578-0400)
Contacts
Molex CLIK-Mate crimp terminals (502579)
Head B
Female D-Sub connector DIN 41652, 9 poles, with mounting screws