![Maxon EPOS 50/5 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/maxon/epos-50-5/epos-50-5_hardware-reference-manual_1745151014.webp)
Specifications
Standards
EPOS4 50/5 Hardware Reference
2-14
CCMC | 2022-04 | rel10445
2.5
Standards
The described device has been successfully tested for compliance with the below listed standards. In prac-
tical terms, only the complete system (the fully operational equipment comprising all individual components,
such as motor, servo controller, power supply unit, EMC filter, cabling etc.) can undergo an EMC test to
ensure interference-free operation.
Important Notice
The device’s compliance with the mentioned standards does not imply its compliance within the final, ready
to operate setup. In order to achieve compliance of your operational system, you must perform EMC testing
of the involved equipment as a whole.
Table 2-6
Standards
Electromagnetic Compatibility
Generic
IEC/EN 61000-6-2
Immunity for industrial environments
IEC/EN 61000-6-3
Emission standard for residential, commercial and light-
industrial environments
Applied
IEC/EN 55022
(CISPR22)
Radio disturbance characteristics / radio interference
IEC/EN 61000-4-3
Radiated, radio-frequency, electromagnetic field immunity test
>10 V/m
IEC/EN 61000-4-4
Electrical fast transient/burst immunity test ±2 kV
IEC/EN 61000-4-6
Immunity to conducted disturbances, induced by radio-
frequency fields 10 Vrms
Others
Environment
IEC/EN 60068-2-6
Environmental testing – Test Fc: Vibration (sinusoidal,
10…500 Hz, 20 m/s
2
)
MIL-STD-810F
Random transport (10…500 Hz up to 2.53 g
rms
)
Safety
UL File Number
Unassembled printed circuit board: E229342
Reliability
MIL-HDBK-217F
Reliability prediction of electronic equipment
Environment: Ground, benign (GB)
Ambient temperature: 298 K (25 °C)
Component stress: In accordance with circuit diagram and
nominal power
Mean Time Between Failures (MTBF): 296'741 hours