PLATFORM WILL NOT LOWER
1.
Check the Battery Cables for damage, and the Battery for a charge.
Replace or recharge as needed. The use of a Voltage Load Tester is
recommended.
2.
Check the two “D” Solenoid Valve Coils (located at the top of each
Column), and the “B” and “C” Valve Coils (located in the Pump Box), for
power.
1/4”
VALVE
COIL
VALVE CARTRIDGE
Place a screwdriver about 1/4” from the Solenoid and
energize the unit. If the screwdriver is not drawn to
the energized solenoid the solenoid must be repaired
or replaced.
SOLENOID
“B”
SOLENOID
“B”
SOLENOID
“D”
SOLENOID
“C”
SOLENOID
“C”
3.
To clean the Valve, remove the Valve Coil
from the Valve Cartridge. Using a paper clip,
push on the Plunger inside the Valve
Cartridge. It should move freely approximately
1/8”. Inspect O-Ring and wash the Cartridge in
solvent to remove any foreign substances
inside the Cartridge. If Plunger still does not
move freely (approx. 1/8”), then replace the
Valve Cartridge.