Operating Instructions
Hazardous Location HLRM Series
MaxLite Hazardous Location HLRM Series
• To reduce the risk of death, personal injury or property damage from fire,
electric shock, falling parts, cuts/abrasions, and other hazards read all
warnings and instructions included with and on the fixture box and all
fixture labels.
• Before installing, servicing, or performing routine maintenance upon
this equipment, follow these general precautions.
• Commercial installation, service and maintenance of luminaires
should be performed by a qualified licensed electrician.
• DO NOT INSTALL DAMAGED PRODUCT!
• Make sure that the supply voltage is the same as the luminaire voltage.
• Do not install where the marked operating temperatures exceed the
ignition temperatures of the hazardous atmosphere.
• Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
• All gasket seals must be clean and undamaged.
WARNING:
RISK OF ELECTRICALSHOCK
Luminaire shall have provision for connection to threaded rigid metal conduit or other wiring methods in
accordance with Article 502 in the National Electrical Code, NFPA 70. Turn off electrical power at fuse or
circuit breaker box before wiring luminaire to the power supply. Turn off the power when you perform any
maintenance. Verify that supply voltage is correct by comparing it with the luminaire label information.
Make sure all electrical and grounded connections in accordance with the National Electrical Code and any
applicable local code requirements and Hazloc requirements and suitable for wiring system. All wiring
connections should be capped with UL approved wire connectors. Luminaire must be supplied by a wiring system
with an equipment grounding conductor.
CAUTION:
RISK OF INJURY
Tightly close when energized for safety; Do not open the luminarie after installation
;
Wear gloves and safety
glasses at all times when removing luminaire from carton, installing,servicing or performing maintenance; Avoid
direct eye exposure to the light source while it is on; Properly handle small parts and destroy packing material, as
these may be hazardous to children.
CAUTION:
RISK OF FIRE
• Keep combustible and other materials that can burn away from luminaire and lamp/lens.
• MIN 90°C SUPPLY CONDUCTORS.
Models:
HLRM Series
Operating characteristic:
© Copyright 2020. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: [email protected]
®
Picture is for illustration purposes only.
Your model may vary.
General Safety Information
This fixture is suitable for use in the following
hazardous (classified) areas as defined by the
National Electrical Code (NEC) and Canadian
Electrical Code (CEC):
Hazardous Locations
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III, Division 1
Page: 1
REV: 07/30/20
Refer to the luminaire nameplate for specific classification
information, maximum ambient temperature suitability and
corresponding operating temperature (T-Code).
Power Model Ambient Temp.
80W
120W
150W
200W
HLRM80
HLRM120
HLRM150
HLRM200
-40°F~+149°F (-40°C~+65°C)
-40°F~+140°F (-40°C~+60°C)
-40°F~+131°F (-40°C~+55°C)