
1
8
PO
WE
R
IN
PO
WER/
SOL
AR
IN
BA
TTER
Y
IN
www
.m
ax
.us
.com
Made
in US
A
BA
TTER
Y
PA
CK
TO
M
OT
OR
CO
NT
ROL
LER
E
1/2
Bat
ter
y V
olt
age
Re
place
Ba
tte
ry
ON
/OF
F
Batt
ery
TE
ST
Ba
tte
ry
Ba
tte
ry
IN
Err
or
F
MA
X B
C-7
Ba
tte
ry
Mod
ule
IMP
O
R
TA
N
T
conn
e
ct
to
“
BA
TTER
Y IN
”
bef
or
e
us
e
E
1/2
Ba
tte
ry V
olt
ag
e
Re
pla
ce
Ba
tte
ry
ON
/OF
F
Ba
tte
ry
TES
T
Ba
tte
ry
Ba
tte
ry I
N
Erro
r
F
MAX
BC-
7
Ba
tte
ry Mo
du
le
Mad
e i
n US
A
A
MAX Magic Box
Kit (sold separately) is required to remotely install the
MAX PS-24 Power Supply.
Remove
MAX PS-24 power supply
from gate operator and install in
MAX Magic Box
, plug in power supply to PS-24 connector.
Wire input AC power to the
MAX PS-24 Power Supply
.
Choose either
115V
or
230V
setting on input AC power selector switch. Run 24V low voltage wires (10 AWG min, not included)
from the
MAX Magic Box
connection and wire to
POWER/SOLAR IN connector
(Polarity Matters!). Plug connector into
POWER/SOLAR IN
port on the gate operator’s
MAX BC-7 battery module
.
NOTE:
A
MAX Magic Box
kit is required for
EACH
gate operator
when using dual gate operators.
IMPORTANT NOTE:
Maximum Control’s
remote power supply technology does
NOT
utilize the battery power from the MAX BC-7 Battery
Module during
NORMAL
gate operation. Battery power is
reserved for back-up power
ONLY when an AC power failure
occurs
. As a result, battery life is
NOT
shortened.
This low voltage system can
CONTINUOUSLY
cycle the gate during
NORMAL
gate operation, perfect for high traffic gate applications.
POWER/SOLAR IN
Port
POWER/SOLAR IN
Connector
(Included in kit).
Connect Input
AC Power wire
(See page 17 for
wiring)
At Gate Operator
Wiring operator
IMPORTANT:
MAX Magic Box and Gate
Operator
MUST EACH
be Properly
GROUNDED
.
Proper grounding is a requirement for
LIGHTNING PROTECTION in lightning prone
areas.
To be effective, ground connections
should be made with a
minimum 12 AWG, 600
volt
insulated wire to a ground point within
10
feet of the MAX Magic Box and gate operator
.
The ground point must be at an electrical panel,
a metallic cold water pipe that runs in the earth,
or a grounding rod.
NOTE:
Beware of existing underground
services.
optional remote power supply kit - max magic box
MAX Magic Box MUST
be Properly GROUNDED
Pos +
GND
Polarity Matters!
Ground Rod
within 10 ft
of Box
NOTE:
Consult city codes
for AC line wiring.
Input Power
To
Operator
24 VDC
At MAX Magic Box
230V
AC
ON
POWE
R
OF
F
MAX
PS
-24
PO
WER
SU
PP
LY
FUSE
7 A
MP
IN
Ma
de
in
USA
Sel
ec
t Input
Vol
ta
ge:
115V
AC or 230V
AC
dis
co
nnect
power
before
ser
vic
in
g u
ni
t
WA
RN
ING
W
AR
NIN
G
HI
G
H
H
IG
H
VOL
TA
G
E
VO
LT
AG
E
!
warrant
y
VO
IDED
if la
bel i
s
REMOV
ED
Input AC Power
Power In
From
PS-24
Pos +
GND
24V Wire in Conduit
10 A
WG Minimum
115 V
AC or
230 V
AC
Input AC Powe
r
MAX PS-24 Power Supply
removed from operator
24V
Wires
10 A
WG
Minim
um
MAX BC-7
Batter
y Module
Gr
ound
Input AC Power Selector Switch
CAUTION:
If power selector switch is
set for
115V
but input power is actually
230 V
, 7 Amp Fuse will blow.
CAUTION:
MAKE SURE CIRCUIT
BREAKER IS OFF BEFORE WIRING
DANGER
HIGH VOLTAGE!
DO NOT TURN POWER
ON AT THIS TIME.
Содержание MAX MEGATRON 2500
Страница 2: ......
Страница 13: ...11 MAX Solar Panel Approx 45 solar installation Refer to Solar application guide ...