MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
4.1.12.1.5
PWRMAN_WUD_CTRL
PWRMAN_WUD_CTRL.pad_select
Field
Bits
Default
Access
Description
pad_select
5:0
000000b
R/W
Wake-Up Pad Select
Selects which pad to modify WUD/Weak latch states.
Pads are numbered from 0-63, where 0-7 corresponds to P0.0-P0.7, 8-15 corresponds to P1.0-P1.7, and so on.
PWRMAN_WUD_CTRL.pad_mode
Field
Bits
Default
Access
Description
pad_mode
9:8
00b
R/W
Wake-Up Pad Signal Mode
Defines WUD signal to be sent to selected pad.
• 0 = Clear/Activate WUD
• 1 = Set WUD Act Hi/Set WUD Act Lo
• 2 = Set Weak Hi/Set Weak Lo
• 3 = No pad state change
PWRMAN_WUD_CTRL.clear_all
Field
Bits
Default
Access
Description
clear_all
12
0
R/W
Clear All WUD Pad States
When set forces all pads into Clr WUD/Weak state until cleared.
Rev.1.3 April 2015
Maxim Integrated
Page 52
Содержание MAX32600