MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
PWRMAN_SVM_EVENTS.v3_3_warning
Field
Bits
Default
Access
Description
v3_3_warning
1
n/a
R/O
3.3V Warning Monitor Event Input
Current state of the associated SVM event input.
PWRMAN_SVM_EVENTS.rtc_warning
Field
Bits
Default
Access
Description
rtc_warning
2
n/a
R/O
RTC Warning Monitor Event Input
Current state of the associated SVM event input.
PWRMAN_SVM_EVENTS.v3_3_reset
Field
Bits
Default
Access
Description
v3_3_reset
3
n/a
R/O
3.3V Reset Monitor Event Input
Current state of the associated SVM event input.
PWRMAN_SVM_EVENTS.vdda_warning
Field
Bits
Default
Access
Description
vdda_warning
4
n/a
R/O
VddA Warning Monitor Event Input
Current state of the associated SVM event input.