MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.4 Timers/Counters
• 0: One Shot Mode
• 1: Continuous Mode
Bit 1 controls operating mode for 16-bit timer 1:
• 0: One Shot Mode
• 1: Continuous Mode
Bit 2 is not used in dual 16-bit timer mode.
TMRn_CTRL.tmr2x16
Field
Bits
Default
Access
Description
tmr2x16
3
0
R/W
Dual 16-bit Timer Mode
This bit determines whether this timer instance operates as a single 32-bit timer or dual 16-bit timers.
• 0: Single 32-bit timer
• 1: Dual 16-bit timers
TMRn_CTRL.prescale
Field
Bits
Default
Access
Description
prescale
7:4
0000b
R/W
Timer Clock Prescale Setting
Determines what divide down value (if any) is used when generating the timer clock from the current system clock. This setting is used by both the 32-bit timer and
by one or both of the 16-bit timers (when enabled). Disabling the 32-bit timer or both 16-bit timers automatically resets this field to 0 (div by 1).
• 0000b: Divide by 1
Rev.1.3 April 2015
Maxim Integrated
Page 601