MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.2 Watchdog Timers
Default
Access
Description
0000 0000 0000 0000 0000 0000 0000 0000b
R/W
WDT0 - Watchdog Clear Register
(Feed Dog)
Write 0xA5,0x5A sequence to clear watchdog timer (feed watchdog)
Reads always return zero.
10.2.5.1.3
WDTn_FLAGS
WDTn_FLAGS.timeout
Field
Bits
Default
Access
Description
timeout
0
0 (POR only)
W1C
Watchdog Timeout Interrupt Flag
Write 1 to clear this flag to 0.
Set to 1 by hardware when the watchdog timer reaches the end of the interrupt period without being cleared.
WDTn_FLAGS.pre_win
Field
Bits
Default
Access
Description
pre_win
1
0 (POR only)
W1C
Watchdog Pre-Window Clear Interrupt Flag
Write 1 to clear this flag to 0.
Set to 1 by hardware when the watchdog timer is cleared before the end of the pre-window period.
WDTn_FLAGS.reset_out
Field
Bits
Default
Access
Description
reset_out
2
0 (POR only)
W1C
Watchdog Reset Flag
Rev.1.3 April 2015