MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
adc_scan7
31:24
00h
R/W
ADC Scan Configuration - Channel 7
• bits 3:0 - mux_ch_sel setting
• bits 5:4 - pga_gain setting
• bit 6 - mux_diff setting
• bit 7 - Not used, should be set to 0
Note
ADC unipolar/bipolar mode and bipolar range must be the same for all channels.
8.3.5.1.11
ADCCFG_RO_CAL0
ADCCFG_RO_CAL0.ro_cal_en
Field
Bits
Default
Access
Description
ro_cal_en
0
0
R/W
Relaxation Oscillator Auto-Calibration Enable
1: Use auto calibration loop register instead of RO factory trim setting.
ADCCFG_RO_CAL0.ro_cal_run
Field
Bits
Default
Access
Description
ro_cal_run
1
0
R/W
Enable Closed Loop Control
1: Enable closed loop control (must set ro_cal_en=1 first)
ADCCFG_RO_CAL0.ro_cal_load
Rev.1.3 April 2015
Maxim Integrated
Page 449