MAX32600 User’s Guide
Communication Peripherals
7.3 UART
7.3.9.1.1
UARTn_CTRL
UARTn_CTRL.rx_threshold
Field
Bits
Default
Access
Description
rx_threshold
2:0
100b
R/W
Receive FIFO Interrupt Threshold
Specifies the depth of receive FIFO that triggers an interrupt. Valid settings are 1-7.
UARTn_CTRL.parity_enable
Field
Bits
Default
Access
Description
parity_enable
4
0
R/W
Parity Enable
• 0:Disable parity
• 1:Enable parity
UARTn_CTRL.parity_mode
Field
Bits
Default
Access
Description
parity_mode
5
0
R/W
Parity Mode Select
• 0:Even parity mode selected
• 1:Odd parity mode selected
UARTn_CTRL.parity_bias
Rev.1.3 April 2015
Maxim Integrated