MAX32600 User’s Guide
Peripheral Management Unit (PMU)
6.3 PMU Programming Details
Figure 6.3: PMU WRITE Op Code Details
INT
• Set to 1 to generate an interrupt to the CPU upon completion of this op code.
STOP
• Set to 1 if this op code is to terminate op code processing after execution.
• This also clears the START bit field in the
register.
6.3.3
PMU Op Code: WAIT (0x02)
The WAIT op code will suspend the execution of subsequent op codes until any of the corresponding bit(s) in the interrupt mask are set. An interrupt mask of all
zeros will terminate execution of this op code. The op code bit settings and operands are shown below.
Rev.1.3 April 2015
Maxim Integrated
Page 198
Содержание MAX32600
Страница 1: ...MAX32600 User s Guide April 2015...