background image

 

 

Application Drawing 

Vi2401A Ethernet Extender over Coax Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

The MaxiiCopper Model Vi2401A is a revolutionary data transmission 

device that extends full-duplex High-Speed Ethernet over existing coax 

infrastructures. It extends 10BaseT signals up to 5,000 ft (1,524m) and 

100BaseT up to 1,800 ft (548m). With Pass Through PoE (PTP™), it 

extends up to 30W PoE power. It employs 

MaxiiCopper

 innovative and 

unique Ethernet extension technology that is designed to take full advan-

tage of high-bandwidth networking cables and maintain a full-duplex 10 or 

100Mb/s Ethernet connection up to the maximum range with minimum 

transmission error and latency.
Vi2401A can connect multiple remote network devices such as Mega-pixel 

IP cameras or VoIP to a central LAN switching fabric with ease.  Its 

dual-rate capability feature provides an easy way to balance the best 

possible network throughput and long-reach distance design.
The Vi2401A is a transceiver device and needs to be deployed on both 

ends of the coaxial cable.  The data rate between the remote and central 

locations is automatically set based on the distance. It is equipped with 

LEDs to provide link status and configured data rate.  No IP setting or 

configurations are required and it is completely transparent to the corporate 

IP network and higher layer protocols. The Coax cable needs to be point to 

point without any branches. Multiple segments can be joined together using 

 Ethernet Extenders

Important Safety Warning

- Set the Master/Slave dip switch to “Master” mode.

- Set the Remote/Local switch to Remote

- Connect the IP camera RJ45 connector to the 10/100BaseT Ethernet port 

of Vi2401A using a standard Cat5/6 cable of maximum 100 m in length.

- Connect one end of the long coax cable to the BNC connector of 

Vi2401A.
The link LED on the 10/100 connector should be “ON” to indicate proper 

connection between the camera and Vi2401A. 

Ethernet Switch/NVR-end Installation

- Set the Master/Slave dip switch to “Slave” mode.

- Set the Remote/Local switch to Local.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

Ethernet port of Vi2401A using a standard Cat5/6 cable of maximum 100 m 

in length.

- Connect one end of the long coax cable to the BNC connector of Vi2401.
The link LED on the 10/100 Ethernet connector should be “ON” to indicate 

proper connection between the switch and Vi2401A. Also the Traffic LED 

on the Coax side should be on and flashing to indicate proper connection.  

While the Link LED, Orange for 100BaseT and Green for 10BaseT, in a 

steady state will indicate confirmed connection between extenders. 

IP Camera

Up to 5,000 ft.

(1,515 m) Coax

Cat-5

Cat-5

Data

NVR

Network Switch

Vi2401A

Vi2401A

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should 

  conform to all local codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage

  wiring.

- To reduce the risk of fire or electrical shock, do not expose these products 

  to rain, moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron

  equipment.

- DO NOT install the unit in a place where the operating ambient tempera

  ture exceeds 75° C.

- Make sure that the external power supply output voltage is in the recom

  mended range. 

- Do not install near any heat sources such as radiators, heat registers, 

  stoves or other apparatus (including DVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at 

  plugs, convenience receptacles, and the point where they exit from the 

  apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long 

  periods of time.

- Refer all servicing to qualified service personnel. Servicing is required

  when the apparatus has been damaged in any way, such as a power 

  supply cord or plug is damaged, liquid has been spilled, or objects have

  fallen into the apparatus, the apparatus has been exposed to rain or 

  moisture, does not operate normally, or has been dropped.

- The mains plug is used as the disconnect device and shall remain readily

  operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

Отзывы: