Comet Executive Gas
Installation
2-21
Follow the procedure below for the type of gas
being used—natural gas, liquefied petroleum gas,
or manufactured gas.
For Natural Gas:
Perform only when the unit is OFF
with power disconnected and COOL.
1.
Turn power OFF at the main disconnect
switch.
WARNING
Do not adjust or test gas
components unless you are
qualified to do so.
2. Connect a U-tube or other water column
manometer upstream of the gas connec-
tion, and measure the static gas pressure.
3.
If the pressure is:
•
Less than 5” (1.25 kPa): Burner may
not work reliably. Correct the gas pres
-
sure before proceeding.
•
5” - 11” (1.25 - 2.75 kPa): Proper op
-
erating range.
•
More than 11” (2.75 kPa): This is a
high pressure gas supply. Installation
of an additional regulator is necessary:
1) The additional regulator must be
mounted according to the manu-
facturer’s specifications.
2)
Open the left endframe door and
measure the incoming gas pressure
to gas valve (Figure 2-20) to make
sure it is now in the proper range
(connect the manometer to the “in”
port on the gas valve, A).
3)
When replacing the plug, use pipe
thread compound to avoid leaks.
Teflon tape is not recommended.
For Liquefied Petroleum Gas
(Propane, Butane):
Perform only when the unit is OFF
with power disconnected and COOL.
1.
Turn power OFF at the main disconnect
switch.
WARNING
Do not adjust or test gas
components unless you are
qualified to do so.
2. Connect a U-tube or other water column
manometer upstream of the gas connec-
tion, and measure the static gas pressure.
3.
If the pressure is:
•
Less than 11” (2.75 kPa): Burner may
not work reliably. Correct the gas pres
-
sure before proceeding.
•
11” - 12” (2.75 - 3.0 kPa): Proper op
-
erating range.
A
B
C
Figure 2-20:
Make sure to check gas operating
pressure (B) as well as upstream
pressure (A).
TOC
INDEX
Содержание Comet Executive Exec-56-G
Страница 1: ...INSTRUCTION MANUAL COMET EXECUTIVE Gas Heated Flatwork Ironer...
Страница 42: ......
Страница 58: ......
Страница 80: ......
Страница 164: ......
Страница 166: ...SC 2 Motor Circuit 115V 1 Phase SC TOC INDEX TOC...
Страница 168: ...SC 4 Motor Circuit 230V 1 Phase SC TOC INDEX TOC...
Страница 170: ...SC 6 Motor Circuit 230V 3 Phase SC TOC INDEX TOC...
Страница 172: ...SC 8 Motor Circuit 415V 3 Phase SC TOC INDEX TOC...
Страница 174: ...SC 10 Motor Circuit 460V 3 Phase SC TOC INDEX TOC...
Страница 176: ...SC 12 Main Electrical Panel 115V 1 Phase SC TOC INDEX TOC...
Страница 178: ...SC 14 Main Electrical Panel 230V 1 Phase SC TOC INDEX TOC...
Страница 180: ...SC 16 Main Electrical Panel 230V 3 Phase SC TOC INDEX TOC...
Страница 182: ...SC 18 Main Electrical Panel 460V 3 Phase SC TOC INDEX TOC...
Страница 184: ......
Страница 185: ...TOC INDEX...
Страница 186: ......
Страница 187: ...TOC INDEX...
Страница 188: ......
Страница 189: ...TOC INDEX...
Страница 190: ......
Страница 192: ......
Страница 194: ......
Страница 196: ......
Страница 197: ...304500 1a TOC INDEX MB TOC...
Страница 198: ...TOC INDEX MB TOC...
Страница 199: ...TOC INDEX MB TOC...
Страница 200: ...TOC INDEX MB TOC...
Страница 221: ...3045069 TOC INDEX MB TOC...
Страница 222: ...TOC INDEX MB TOC...
Страница 223: ...TOC INDEX MB TOC...
Страница 224: ...TOC INDEX MB TOC...
Страница 225: ...46 7796 6 90 836 4 1 36 38 6 7 3 4 1 0 3980 8 0 2 2 7 6 7 3 238 3 68 8 2 7 6 7 8 8 2 83 2 4392 7 TOC INDEX MB TOC...
Страница 229: ...TOC INDEX MB TOC...
Страница 230: ...TOC INDEX MB TOC...
Страница 231: ...TOC INDEX MB TOC...
Страница 232: ...TOC INDEX MB TOC...
Страница 236: ......
Страница 238: ......
Страница 244: ......