Comet Executive Gas
Troubleshooting
6-13
WARNING
Only trained personnel with experience
in gas, electrical or mechanical repair
should troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
BURNER IGNITION
ISSUE
POSSIBLE CAUSE
SOLUTION
Flame Does Not Travel Down
the Entire Length of the
Burner
1. External and/or internal
manual gas valves are
closed or partially closed.
• Open the manual gas valves.
2. Gas pressure is wrong.
• Refer to the
Gas Flow: Poor, Irregular,
None
issue below.
3. Burner tips are clogged.
• Clean. Refer to
Gas Flow: Poor, Irregular,
None
1. External and/or internal
manual gas valves are
closed.
• Make sure the external and internal
manual gas valves are open before
starting the burner.
2. Incoming gas pressure is
too high or too low due to
an incorrect gas supply or
other gas-burning equip-
ment in the area.
• Check the incoming gas pressure during
periods of peak demand and adjust, if
necessary. Refer to
.
3. Gas valve coil or ignition
control is bad.
• Check the voltage at the gas valve coil
when the burner system calls for heat.
-If 24 VAC is present but the valve
doesn’t open, the gas valve is bad and
must be replaced.
-If the voltage is well below 24 VAC,
check the line voltage to the unit.
-If there is no voltage at all, the ignition
control may need to be replaced.
4. On-site gas demand is
irregular due to other equip-
ment.
• Check the incoming gas pressure during
periods of peak demand and adjust, if
necessary. Refer to
.
Burner Starts Normally, Then
Shuts Down
1.
Gas flow to the burner is
insufficient.
• Refer to the
Gas Flow: Poor, Irregular,
None
issue above.
2.
Exhaust system backflow
has caused sail switch to
close.
• Check/clean exhaust system as neces-
sary. For cleaning instructions, refer
Check and Clean Sail Switch and
Exhaust Blower Wheel on page 4-11
• Check/replace defective sail switch.
3. If no other problems are
found and the burner will
not stay lit, the ignition
control is bad.
• Check. Replace, if necessary.
TOC
INDEX
Содержание Comet Executive Exec-56-G
Страница 1: ...INSTRUCTION MANUAL COMET EXECUTIVE Gas Heated Flatwork Ironer...
Страница 42: ......
Страница 58: ......
Страница 80: ......
Страница 164: ......
Страница 166: ...SC 2 Motor Circuit 115V 1 Phase SC TOC INDEX TOC...
Страница 168: ...SC 4 Motor Circuit 230V 1 Phase SC TOC INDEX TOC...
Страница 170: ...SC 6 Motor Circuit 230V 3 Phase SC TOC INDEX TOC...
Страница 172: ...SC 8 Motor Circuit 415V 3 Phase SC TOC INDEX TOC...
Страница 174: ...SC 10 Motor Circuit 460V 3 Phase SC TOC INDEX TOC...
Страница 176: ...SC 12 Main Electrical Panel 115V 1 Phase SC TOC INDEX TOC...
Страница 178: ...SC 14 Main Electrical Panel 230V 1 Phase SC TOC INDEX TOC...
Страница 180: ...SC 16 Main Electrical Panel 230V 3 Phase SC TOC INDEX TOC...
Страница 182: ...SC 18 Main Electrical Panel 460V 3 Phase SC TOC INDEX TOC...
Страница 184: ......
Страница 185: ...TOC INDEX...
Страница 186: ......
Страница 187: ...TOC INDEX...
Страница 188: ......
Страница 189: ...TOC INDEX...
Страница 190: ......
Страница 192: ......
Страница 194: ......
Страница 196: ......
Страница 197: ...304500 1a TOC INDEX MB TOC...
Страница 198: ...TOC INDEX MB TOC...
Страница 199: ...TOC INDEX MB TOC...
Страница 200: ...TOC INDEX MB TOC...
Страница 221: ...3045069 TOC INDEX MB TOC...
Страница 222: ...TOC INDEX MB TOC...
Страница 223: ...TOC INDEX MB TOC...
Страница 224: ...TOC INDEX MB TOC...
Страница 225: ...46 7796 6 90 836 4 1 36 38 6 7 3 4 1 0 3980 8 0 2 2 7 6 7 3 238 3 68 8 2 7 6 7 8 8 2 83 2 4392 7 TOC INDEX MB TOC...
Страница 229: ...TOC INDEX MB TOC...
Страница 230: ...TOC INDEX MB TOC...
Страница 231: ...TOC INDEX MB TOC...
Страница 232: ...TOC INDEX MB TOC...
Страница 236: ......
Страница 238: ......
Страница 244: ......