MAXDATA PLATINUM 100 Server 

MAXDATA PLATINUM 100 Server

System Manual

Содержание PLATINUM 100 I

Страница 1: ...1 MAXDATA PLATINUM 100 Server MAXDATA PLATINUM 100 Server System Manual ...

Страница 2: ...2 Contents ...

Страница 3: ...ardware Management ASIC 14 Fan Monitoring 14 Real Time Clock CMOS SRAM and Battery 14 Legacy USB Support 15 IDE Support 16 IDE Interfaces 16 BIOS 16 PCI Auto Configuration 16 PCI IDE Support 17 Language Support 17 Custom Splash Screen 17 Boot Options 17 CD ROM and Network Boot 17 Booting Without Attached Devices 18 Fast Booting Systems with Intel Rapid BIOS Boot 18 Intel Rapid BIOS Boot 18 BIOS Se...

Страница 4: ...7 NIC Connector and Status LEDs 28 Hardware Monitoring 28 3 Regulatory and Integration Information 29 Product Regulatory Compliance 29 Product Safety Compliance 29 Product EMC Compliance 29 Product Regulatory Compliance Markings 29 Electromagnetic Compatibility Notices 30 FCC USA 30 Europe CE Declaration of Conformity 30 Installation Precautions 31 Installation Requirements 31 Prevent Power Supply...

Страница 5: ...es 9 2 Supported Processors 11 3 Supported Memory Configurations 11 4 Supervisor and User Password Functions 19 5 Effects of Pressing the Power Switch 21 6 Power States and Targeted System Power 21 7 Wake up Devices and Events 22 8 Fan Connector Function Operation 23 9 PCI Bus Characteristics 25 10 PCI Bus Configuration IDs 25 11 Video Modes 27 12 Product Certification Markings 29 ...

Страница 6: ...6 Contents ...

Страница 7: ...o peripheral devices are not tight Make sure that all power and connection cables are positioned so that they are not trip hazards When you save data to your server s hard disks or to a floppy disk they are stored as magnetic information on the media Make sure that they are not damaged by magnetic or electromagnetic fields Because the electronics in your computer can be damaged by jarring no mecha...

Страница 8: ... Parallelport H USB Connector 2 D Serial port A Serieller Port A I NIC 2 E VGA port Powering up the system At the front of the case you can find the neccessary controls like power button reset button and the HDD Leds Press the power button onte time briefly in order to boot the server Figure 2 The Controls A Power switch B Reset switch C Power LED D HDD LED ...

Страница 9: ...ral Interfaces Two external USB ports with an additional internal header providing two optional USB ports for front panel support One serial port and one serial port header One parallel port Two IDE interfaces with UDMA 33 ATA 66 100 support One floppy drive interface with support for two drives Diskette A and Diskette B PS 2 keyboard and mouse ports Expansion Capabilities One independent PCI bus ...

Страница 10: ...ller hub ICH2 E Back panel connectors T HDD LED connector F System fan fan 2 U Configuration jumper block G 12 V auxiliary power connector V Front panel header H µPGA478 processor socket W System fan fan 1 I Intel 82845E memory controller hub MCH X Secondary RAID IDE connector J Chassis fan Y Primary RAID IDE connector K DIMM1 socket Z Battery L DIMM0 socket AA Front panel USB connector M Serial p...

Страница 11: ...bit 8 M x 16 empty 4 128 MB DS 64 Mbit 8 M x 8 8 M x 8 16 Note 1 128 MB SS 128 Mbit 16 M x 8 empty 8 128 MB SS 256 Mbit 16 M x 16 empty 4 256 MB DS 128 Mbit 16 M x 8 16 M x 8 16 Notes 1 and 2 256 MB SS 256 Mbit 32 M x 8 empty 8 256 MB SS 512 Mbit 32 M x 16 empty 4 512 MB DS 256 Mbit 32 M x 8 32 M x 8 16 Notes 1 and 2 512 MB SS 512 Mbit 64 M x 8 empty 8 1024 MB DS 512 Mbit 64 M x 8 64 M X8 16 Notes...

Страница 12: ...t for ACPI Rev 1 0b compliant power management Intel 82801BA I O Controller Hub ICH2 The Intel 82801BA ICH2 has these features 33 MHz Peripheral Component Interface PCI Local Bus slots supporting PCI specifi cation Rev 2 2 Support for the Low Pin Count LPC interface Integrated IDE controller supports Ultra ATA 66 100 mode and Ultra DMA 33 mode Integrated LAN media access controller Universal Seria...

Страница 13: ...as one serial port connector and one serial port header The serial port A connector is located on the back panel The serial port B header is located near the main power connector The serial ports NS16C550 compatible UART supports data transfers at speeds up to 115 2 kb s with BIOS support Parallel Port The 25 pin D Sub parallel port connector is located on the back panel In the BIOS Setup program ...

Страница 14: ...itoring of processor temperature Power supply monitoring 5 V 3 3 V 1 5 V 3 3 VSB and Vccp to detect levels above or below acceptable values SMBus interface Fan Monitoring The Hardware Management ASIC provides four fan tachometer inputs Monitoring can be implemented using Intel LANDesk Client Manager or third party software Real Time Clock CMOS SRAM and Battery The real time clock provides a time o...

Страница 15: ...able Use shielded cable that meets the requirements for full speed devices Legacy USB support operates as follows 1 When the user applies power to the computer legacy support is disabled 2 POST begins 3 Legacy USB support is enabled by the BIOS allowing the user to use a USB keyboard to enter and configure the BIOS Setup program and the maintenance menu 4 POST completes 5 The operating system load...

Страница 16: ...0 drive can be configured as a boot device by setting the BIOS Setup program s Boot menu to one of the following ARMD FDD ATAPI removable media device floppy disk drive ARMD HDD ATAPI removable media device hard disk drive BIOS The MAXDATA PLATINUM Server board uses an Intel AMI BIOS that is stored in the Firmware Hub FWH and can be updated using a disk based program The FWH contains the BIOS Setu...

Страница 17: ...help messages are supported in two languages US English and Spanish Additional languages may be flashed in if desired German Italian and French available The default language is US English which is present unless another language is selected in the BIOS Setup program Custom Splash Screen During POST an Intel splash screen is displayed by default This splash screen can be replaced with a custom spl...

Страница 18: ... to a boot time that might be so fast that necessary logo screens and POST messages cannot be seen This boot time may be so fast that some drives might be not be initialized at all If this condition should occur it is possible to introduce a programmable delay ranging from three to 30 seconds using the Hard Disk Pre Delay feature of the Advanced Menu in the IDE Configuration Submenu of the BIOS Se...

Страница 19: ...apabilities operational status and installation dates for system components The MIF database defines the data and provides the method for accessing this information The BIOS enables applications such as third party management software to use SMBIOS The BIOS stores and reports the following SMBIOS information BIOS data such as the BIOS revision level Fixed system data such as peripherals serial num...

Страница 20: ...hardware on the server board monitors the ring indicate RI input of the serial port Resume on Ring The operation of Resume on Ring can be summarized as follows Resumes operation from the ACPI S1 Requires only one call to access the server Detects incoming call similarly for external and internal modems does not use the Wake on Ring connector Requires modem interrupt be unmasked for correct operati...

Страница 21: ...ACPI G1 sleeping state Less than four seconds Wake up ACPI G0 working state Sleep ACPI G1 sleeping state More than four seconds Power off ACPI G2 G5 Soft off System States and Power States Under ACPI the operating system directs all system and device power state transitions The operating system puts devices in and out of low power states based on user preferences and knowledge of how devices are b...

Страница 22: ...er board provides several power management hardware features including Power connector Fan connectors LAN wake capabilities Instantly Available PC technology Resume on Ring Wake from USB Wake from PS 2 keyboard PME wake up support LAN wake capabilities and Instantly Available PC technology require power from the 5 V standby line The sections discussing these features describe the incremental stand...

Страница 23: ...chometer input of the Hardware Management ASIC LAN Wake Capabilities CAUTION For LAN wake capabilities the 5 V standby line for the power supply must be capable of providing adequate 5 V standby current Failure to provide adequate standby current when implementing LAN wake capabilities can dama e the power supply LAN wake capabilities enable remote wake up of the computer through a network The LAN...

Страница 24: ...D Resume on Ring The operation of Resume on Ring can be summarized as follows Resumes operation from ACPI S1 state Requires only one call to access the computer Detects incoming call similarly for external and internal modems Requires modem interrupt be unmasked for correct operation Wake from USB USB bus activity wakes the computer from an ACPI S1 state NOTE Wake from USB requires the use of a US...

Страница 25: ...the Ultra DMA 33 ATA 66 100 connectors will be allocated a GPIO to disable the device Device IDs IDSEL Each device under the PCI hub bridge has its IDSEL signal connected to one bit of AD 31 16 which acts as a chip select on the PCI bus segment in configuration cycles This determines a unique PCI device ID value for use in configuration cycles The following table shows each IDSEL value for the PCI...

Страница 26: ...are drive three drives RAID 0 One to four drives are required RAID 0 configurations are used for high performance applications as it doubles the sustained transfer rate of its drives RAID 1 configurations primarily used for data protection It creates an identical drive backup to a secondary drive Whenever a disk write is performed the controller sends data simultaneously to a second drive located ...

Страница 27: ...eo Memory Interface The memory controller subsystem of the Rage XL arbitrates requests from direct memory interface the VGA graphics controller the drawing coprocessor the display controller the video scalar and hardware cursor Requests are serviced in a manner that ensures display integrity and maximum CPU coprocessor drawing performance The server board supports a 8 MB 2048K x 32bit x 4 Banks SD...

Страница 28: ...ver board has an integrated Hardware Management ASIC that is responsible for hardware monitoring Together the Hardware Management ASIC and the Intel LANDesk Client Manager LDCM 6 3 software provide basic server hardware monitoring which alerts a system administrator if a hardware problem occurs on an Intel Server board based system The Intel LDCM software is for use with Windows 2000 Server and Wi...

Страница 29: ...ed and verified to comply with the following electromagnetic compatibility EMC regulations when installed a compatible Intel host system FCC Class A Verification Radiated Conducted Emissions USA CISPR 22 3rd Edition Class A Radiated Conducted Emissions International EN55022 Class A Radiated Conducted Emissions European Union EN55024 Immunity European Union CE EMC Directive 89 336 EEC European Unio...

Страница 30: ...ry to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by...

Страница 31: ...ovided by chassis and module suppliers you increase safety risk and the possibility of noncompliance with regional laws and regulations Prevent Power Supply Overload Do not overload the power supply output To avoid overloading the power supply make sure that the calculated total current loads of all the modules within the computer is less than the output current rating of each of the power supplie...