Menu # 10 -

 

PUMP TEMP1 

Read-only menu, displays the temperature of pump 

Menu # 11 -

 

PUMP TEMP2 

Read-only menu, displays the temperature of pump 

Menu # 12 -

 

+5V Reads 

Read-only menu, displays the v5V 

Menu # 13 -

 

-5V Reads 

Read-only menu, displays the voltage -5V 

Menu # 14 -

 

UNIT TEMP 

Read-only menu, displays the temperature of chassis

 

Menu # 15 -

 

IP 

Adjustable list, displays the IP address of SNMP 

Menu # 16 -

 

Sub 

Adjustable list, display the address of net mask 

Menu # 17 -

 

GW 

Adjustable list, displays the gateway address of SNMP 

Menu # 18 -

 

TR1 

Adjustable list, displays the TRAP1 address of SNMP 

Menu # 19 -

 

TR2 

Adjustable list, displays the TRAP2 address of SNMP 
 

10.1.3

 

Menu assistant manual 

1. 

 

Input power (INPUT): 
Input power >+10 dBm, display HIGHER; 
Input power <-10 dBm, display LOWER.   

2. 

 

Output (OUTPUT): 
When  input  displays  HIGHER  or  LOWER,  the  output  power 
displays NO OUTPUT. 

3. 

 

Laser temperature (TEMP): °C. The laser temp is set in the range 
of 20°C~30°C. If the detected temp exceeds the range, the red 
light will show an alarm and the power supply of the laser will shut 
off automatically. 

 

4. 

 

Bias (BIAS): Bias is the key index of the laser. If the fixed range is 
exceeded,  the  power  supply  of  the  laser  will  be  shut  off 
automatically to protect the laser   