Menu # 10 -
PUMP TEMP1
Read-only menu, displays the temperature of pump
Menu # 11 -
PUMP TEMP2
Read-only menu, displays the temperature of pump
Menu # 12 -
+5V Reads
Read-only menu, displays the v5V
Menu # 13 -
-5V Reads
Read-only menu, displays the voltage -5V
Menu # 14 -
UNIT TEMP
Read-only menu, displays the temperature of chassis
Menu # 15 -
IP
Adjustable list, displays the IP address of SNMP
Menu # 16 -
Sub
Adjustable list, display the address of net mask
Menu # 17 -
GW
Adjustable list, displays the gateway address of SNMP
Menu # 18 -
TR1
Adjustable list, displays the TRAP1 address of SNMP
Menu # 19 -
TR2
Adjustable list, displays the TRAP2 address of SNMP
10.1.3
Menu assistant manual
1.
Input power (INPUT):
Input power >+10 dBm, display HIGHER;
Input power <-10 dBm, display LOWER.
2.
Output (OUTPUT):
When input displays HIGHER or LOWER, the output power
displays NO OUTPUT.
3.
Laser temperature (TEMP): °C. The laser temp is set in the range
of 20°C~30°C. If the detected temp exceeds the range, the red
light will show an alarm and the power supply of the laser will shut
off automatically.
4.
Bias (BIAS): Bias is the key index of the laser. If the fixed range is
exceeded, the power supply of the laser will be shut off
automatically to protect the laser