14.0
SPECIFICATIONS
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 59 of 60
Supply Voltage
24 VDC,
10%, 250 mADC, 6 VA
Fuse: F1
2.5 amp, Littlefuse Part No. 21602.5, or
Wickmann Part No. 19194-058-FS
Enclosure
IP20 (IEC529)
Climatic Class:
3K3 (EN60721)
Temperature Range:
Operating
0
C to 50
C
Storage
-30
C to +80
C
Relative Humidity
5% to 85%
Pollution Degree:
2 (IEC664-1)
Altitude:
0 to 2000 m
Compatible Residual Current
Device Types:
A or B (IEC755)
Worst Case Fault Current:
2.5 amp
Inputs:
Load cell
2.1 millivolts/volt using +5 and -5 VDC (10 VDC)
across one 350 ohm sensor or two 350 ohm sensors
in parallel. 65 mADC maximum excitation current.
Tension Setpoint
0 to +10 VDC, 0.25 mADC maximum, or 1K to 10K ohm potentiometer
Manual Setpoint
0 to +10 VDC, 0.25 mADC maximum, or 1K to 10K ohm potentiometer
Position Setpoint
0 to +10 VDC, 0.25 mADC maximum, or 1K to 10K ohm potentiometer
Dancer Input
0 to +10 VDC, 0.25 mADC maximum, or 1K to 10K ohm potentiometer
Diameter Input
0 to +10 VDC, 0.25 mADC maximum
E-Stop
switch closure or 5 VDC or 24 VDC active High/Low logic, 8 mADC maximum
Run/Stop
switch closure or 5 VDC or 24 VDC active High/Low logic, 8 mADC maximum
Tension Off
switch closure or 5 VDC or 24 VDC active High/Low logic, 8 mADC maximum
Auto/Manual
switch closure or 5 VDC or 24 VDC active High/Low logic, 8 mADC maximum
Outputs:
Torque (Main Output)
0 to +10 VDC., 1 mADC maximum,
4 to 20 mADC, 500 ohms maximum,
-10 to +10 VDC, 1 mADC maximum
Tension meter or
0 to 1 mADC or 0 to +10 VDC analog
Inverse Diameter output
Communications:
Ethernet
TCP/IP Web server interface
FTP Client
Modbus/TCP Slave