TROUBLESHOOTING
www.maxcessintl.com
MAGPOWR DTR-65
MI 850A349 1 D
Fault description
Probable cause
Solution
Reference
Er 10 at power-up
Sensor White (S+) or Black (S-
) wire disconnected
Check sensor wiring.
Figure 3. DTR-65 wiring
Er 11 at powr-up
Sensor Red (P+) wire
disconnected
Check sensor wiring.
Figure 3. DTR-65 wiring
Er 12 at power-up
Sensor Green (P-) wire
disconnected
Check sensor wiring.
Figure 3. DTR-65 wiring
Er 13 at power-up
Sensor Failure or other mis-
wiring error Example: Green
and White wire swapped,
etc.
Check sensor wiring.
Figure 3. DTR-65 wiring
Display not lighted
No power
Check power wiring
Figure 3. DTR-65 wiring
Fuse(s) blown
Check fuse(s) in DTR-65.
Fuse ratings in Specifications;
p. 8-1
Fuse Replacement; p. 6-1
Analog outputs not
changing with the
displayed tension
Analog output shorted
Check Analog output wiring.
Figure 3. DTR-65 wiring
Analog output range
misconfigured
Check parameters P.06
through P0.11.
––
Analog output not calibrated
Perform output calibration
CAL0.
––
Alarm output not working
Alarm not wired correctly
Check alarm wiring.
Figure 3. DTR-65 wiring
Alarm not configured
correctly
Check parameters P.13
through P.18
––
Remote zero not zeroing
tension
Remote zero input not wired
correctly
Check remote zero wiring.
3. DTR-65 wiring
Digital input threshold level
not set correctly
Check parameter P.12
––
Displayed tension is
reading negative value
with increasing tension.
Tension polarity is wrong
Check parameter P.20.
––
Cannot change
parameters or perform
calibration.
Password protection is active
Enter the password into P.00 to
unlock the DTR-65.
The master unlock password is
6195.
––