Maxcess MAGPOWR DTM Скачать руководство пользователя страница 1

 

 

Digital Tension Meter 

Instruction Manual 

 

www.maxcessintl.com 

DTM 

MI 850A329 1 G 

Page 1 of 4 

 

 
All of the information herein is the exclusive proprietary 
property of Maxcess International and is disclosed with 
the understanding that it will be retained in confidence 
and will neither be duplicated nor copied in whole or in 
part nor be used for any purpose other than for which 
disclosed. 

Copyright 2008, all rights reserved. Periodically there will 
be updates to this manual. The latest version is available 

on our website or by calling your regional office listed on 
the back page of this publication. 

 

              CAUTION: Read complete                    CAUTION: 
              instructions prior to installation               Risk of electric 
               and operation of the unit.                       shock. 

 

 
 
 
 
 
 
 
 
 
 

 UL Recognized Component 

 File #E308360 

 
 

 

LCD WITH RED BACKLIGHTING 

 

0 to 1 mADC Input 

 

0.6 INCH (15.2 mm) HIGH LCD DIGITS  

 

BUILT-IN SCALING PROVIDED 

 

AUTO ZEROING CIRCUIT 

 

SELECTABLE DECIMAL POINTS 

 

WIRE CONNECTIONS MADE VIA SCREW CLAMP TYPE 
TERMINALS 

 

FITS DIN STANDARD CUT-OUT 2.68"  
(68 mm) x 1.30" (33 mm) 

 

NEMA 4X/IP65 SEALED FRONT PANEL BEZEL 

 

9 TO 28 VDC POWERED 

 

 

1.0  DESCRIPTION 

The DTM Digital Tension Meter is designed and manufactured 
using the latest technology for a high quality, compact, afford-
able instrument for use in industrial environments. Each unit has 
a 3-1/2-digit LCD display with 0.6 inch (15.2 mm) high digits and 
a DIP switch selectable decimal point. 

The units are constructed of a lightweight, high impact plastic 
case with a clear viewing window. The sealed front panel meets 
NEMA 4X/IP65 specifications for wash-down and/or dusty 
environments, when properly installed. 

 

2.0  SAFETY SUMMARY 

All safety related regulations, local codes and instructions that 
appear in the manual or on equipment must be observed to 
ensure personal safety and to prevent damage to either the 
instrument or equipment connected to it. If equipment is used 
in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired. 

 

3.0  SPECIFICATIONS 

1.  DISPLAY:  

3-1/2-digit (-1999 to 1999), 0.6" (15.2 mm) high 

digits. Minus (-) sign is displayed when current is negative. 

2.  DECIMAL POINTS:  

DIP switch selectable decimal points 

allow the display to be read in tenths, hundredths or 
thousandths. 

3.  POWER REQUIREMENTS:

  9 to 28 VDC @ 35 Ma typ.,  

50 mA max. Above 26 VDC, derate operating temperature  
to 50°C. 

4.  INPUT RANGES:  

±1.000 mADC 

5.  ACCURACY:  

(@ 23°C, less than 85% RH) ±(0.1% + 1 digit) 

6.  OVERRANGE RATINGS, PROTECTION & INDICATION:

 

9 to 28 VDC power circuit is not isolated from the signal 
circuit. 

Max Input Current:

  10mA 

Overrange Indication:

  Overrange is indicated by a "1" 

displayed in the most significant digit and the blanking of the 
three least significant digits. 

7.  READING RATE:  

2.5 readings per second 

8.  RESPONSE TIME:

  1.5 seconds to settle for a step change 

9.  NORMAL MODE REJECTION:

  60 dB 50/60 Hz 

10. INPUT IMPEDANCE:

 

200 Ω 

11. CERTIFICATIONS AND COMPLIANCES:  

SAFETY 

UL Recognized Component, File # E308360, UL61010A-1, CSA 
C22.2 No. 61010-1 
Recognized to U.S. and Canadian requirements under the 
Component 
Recognition Program of Underwriters Laboratories, Inc. 
Type 4X Enclosure rating (Face only), UL50 
Issued by Underwriters Laboratories, Inc. 
IEC 61010-1, EN 61010-1: Safety requirements for electrical 
equipment for measurement, control, and laboratory use, Part 1. 
IP65 Enclosure rating (Face only), IEC 529

Отзывы: