CALIBRATE TENSION THROUGH FIELDBUS
www.maxcessintl.com
DLCA NET-S1
MI 850A374 1 A
Page 54 of 67
9.0
Calibrate tension through the fieldbus procedure
The DLCA NET-S1 uses Precision calibration. Precision calibration
is used when applying a known weight with a rope in the web
path to the load cells for calibration. Typically this known weight
should be 10% of the load cell rating or greater.
The
Command Interface
is used to perform the calibrations.
A command request is entered in the
Command Request
. The
Command Response
will show the progress of the command and
when the command is complete. Errors will also be shown.
Parameters for Tension Zone 1 can be accessed in the group
Configuration Tension 1
and those for Tension Zone 2 can be
accessed in the group
Configuration Tension 2
.
LC1 - Roll Weight load cells on channel 1.
LC2 - Web Tension Load Cells on channel 2.
RW - Roll Weight
T - Web Tension
Figure 8. Apply calibration tension