background image

 

 

Fife GMA-BL Actuator Controller 

Quick-Start Manual 

 

 

EN 

 

MI 2-264 1 B

 

 
 

Содержание Fife GMA-BL

Страница 1: ...Fife GMA BL Actuator Controller Quick Start Manual EN MI 2 264 1 B...

Страница 2: ......

Страница 3: ...ON 1 1 Copyright information 1 1 General information 1 1 Language 1 1 FEATURES 2 1 Display definitions 2 1 Button functions and definitions 2 3 Status bar definitions 2 5 OPERATION 3 1 System setup 3...

Страница 4: ...le or in part nor be used for any purpose other than for which disclosed This Instruction Manual is intended to be used in addition to the GMA BL Actuator Controller User Manual Figure Sheet 2 265 Gen...

Страница 5: ...the current Operation Mode selection by displaying the corresponding button in a green color Other buttons are blue 2 The horizontal section along the top above the line contains the status bar which...

Страница 6: ...ter and Manual and indicates the current Operation Mode selection by displaying that button in a green color 3 The section just below the Operation Mode buttons indicates the current Operation Mode th...

Страница 7: ...ucer MANUAL This button initiates the Manual mode No correction is applied to the actuator SENSOR This button is used to select the sensor s to be used for monitoring the web position when the system...

Страница 8: ...ARROWS These buttons are used in the menu system to page forward backward when multiple pages of menu choices are available The arrows will appear disabled grayed out when no more choices are availab...

Страница 9: ...ENU TIMEOUT The menu screens in the operator interface close automatically after 3 minutes of touch screen inactivity The inactivity timeout option and the timeout value are configurable The clock ico...

Страница 10: ...ERROR This error icon appears when the input voltage motor rail voltage or internal 12 volt power is outside acceptable range NETWORK ERROR This icon appears when the operator interface is unable to...

Страница 11: ...being used they must be calibrated independently Refer to Figure 3 and Figure 4 shown on the following page 1 Press the SETUP button to enter the Setup menus 2 Press the SENSOR SETUP icon to enter the...

Страница 12: ...ion of the buttons 1 Select the desired sensor mode by pressing the SENSOR SELECTION button 2 Press the SETUP button to enter the Setup menus 3 Press the AUTOSETUP icon to enter the AUTOSETUP menu 4 P...

Страница 13: ...ssist in the Gain adjustment 4 Press the ACCEPT button to save the new Gain value 5 Press the BACK or HOME button to return to the Operator Level screen 12 To manually change the Guide Point while in...

Страница 14: ...he Guide Point is changed while in Automatic Mode the change is effective immediately but if the Guide Point is changed while in Manual Mode or Servo Center modes the change is effective when Automati...

Страница 15: ......

Страница 16: ...sales maxcess eu www maxcess eu CHINA Tel 86 756 881 9398 Fax 86 756 881 9393 info maxcessintl com cn www maxcessintl com cn INDIA Tel 91 22 27602633 Fax 91 22 27602634 india maxcessintl com www maxc...