INSTALLATION

3 - 8

DSE-15

www.maxcess.eu

MI 1094 1

Electrical connection

ATTENTION

The sensor could be damaged.

The safe function of the sensor and the system is only 

guaranteed if it is properly installed.

Electrical connections should always be made or disconnected 

on the sensor while there is no electrical power in the system.

When attaching the connector with the jack on the sensor, 

pay close attention to the guide and groove! The connector and 

jack must not be connected with incorrect orientation or by 

force, as this will destroy the sensor.

Electrical lines must not be subjected to any mechanical 

loads.

The sensor must be connected to the web guide controller 

according to the system diagram in the system 

documentation.

Note:

Normally the sensor must be connected to the web guide 

controller with a cable on the corresponding sensor input. In 

some cases two sensors can be connected to a sensor input on 

the web guide controller via a Y cable or an external distributor 

box.

only for sensor cables with open wire ends
Personnel: Qualified electrician

The sensor may only be connected electrically by a qualified 

electrician.

– The power supply voltage must be externally fused.



Power supply, page 9-2

– The external 12V/24V DC voltage must be generated and 

supplied in accordance with the criteria for protective extra-

low voltage (PELV). 

– The negative potential must be connected to ground.
– The sensor housing must be grounded via the cable screen.



see also the drawing for the sensor cable in the system 

documentation

Содержание FIFE DSE-15

Страница 1: ...FIFE GUIDING SOLUTIONS FIFE DSE 15 Operating Instructions Reflected light sensor MI 1094 1 EN...

Страница 2: ...Transport and storage 3 1 Included with delivery 3 1 Mounting 3 1 Mounting location 3 2 Dimensions 3 2 Mechanical fastening 3 2 Distance between reflector and sensor 3 5 Alignment of reflector and se...

Страница 3: ...II CONTENTS DSE 15 www maxcess eu MI 1094 1 MI10941 IVZ fm Properties 9 1 Electrical connection 9 2 Pin assignment 9 2 Standards 9 2 SERVICE 10 1 Requests for Service 10 1 Adresses 10 1...

Страница 4: ...ating Instructions are directed to both the system construction master as well as the operator who uses the sensor in production line Read operating instructions The Operating Instructions must be rea...

Страница 5: ...ve to ambient light and reflections The light source generates a red light Depending on the amount of the sensor field of view covered by the material web a portion of the light strikes the reflector...

Страница 6: ...s an output signal in the range from 4 to 20mA This can be used to establish a wire break proof connection to external devices An integrated LED display shows information about operation states direct...

Страница 7: ...cable national state and local requirements for accident prevention and environmental protection Information about safety instructions The safety instructions and symbols described in this section are...

Страница 8: ...in damage to the device or system Qualified electrician The electrical components may only be connected and disconnected by a qualified electrician Read operating instructions Follow these operating...

Страница 9: ...ction or disconnection Specialized staff Only by a qualified electrician Control during operation Specialized staff Machine and system operators etc Personnel or trainees trained and supervised by the...

Страница 10: ...or step There is a danger that the sensor will become damaged breaking off snapping resulting in personal injury Residual risks Installing the product in a machine system makes it possible to form cl...

Страница 11: ...ctronic components of the sensor may be damaged Included with delivery Reflected light sensor DSE 15 The model designation and part number are on the nameplate on the housing Mounting bracket and fast...

Страница 12: ...electronic components may be damaged Not in places where there is a risk of explosions Dimensions Mechanical fastening Drill holes are available on the housing for fastening the sensor in place A larg...

Страница 13: ...the sensor onto the sensor bracket Sensor bracket Type MO figure 3 3 Sensor bracket Type MB figure 3 4 Special sensor brackets available on request 3 Slide the mounted unit onto the square bar and fa...

Страница 14: ...www maxcess eu MI 1094 1 Figure 3 3 DSE 15 on sensor bracket type MO Type A B C VK MO 20 8 69 39 15 20 MO 25 8 71 42 19 25 Figure 3 4 DSE 15 on sensor bracket type MB Type X Y Z VK MB 20 25 15 5 17 5...

Страница 15: ...usable Depending on the material of the controlled web it is possible a grinding of the material web or a plane change could strike and damage the sensor or reflector Make certain there is sufficient...

Страница 16: ...istance must be maintained for reflectors with a rough structure table and figure 3 5 Alignment of reflector and sensor To prevent an undesirable change in the web position and guide point when the we...

Страница 17: ...1 Reflector 2 Material web 3 Web edge HS Plane change RPV Guide point change with a tilted sensor due to a plane change of the web Figure 3 6 Undesirable guide point change with plane change due to fa...

Страница 18: ...controller according to the system diagram in the system documentation Note Normally the sensor must be connected to the web guide controller with a cable on the corresponding sensor input In some cas...

Страница 19: ...y the material web when the sensor is working in the regular operation state LEDs in normal operation page 6 1 Indicates that the sensor has been set up to the reflector when the two outer LEDs altern...

Страница 20: ...not be any material between the sensor and reflector The protector of the sensor and the reflector must be clean Setup 1 Switch the web guide controller to Manual operation mode 2 Align the light beam...

Страница 21: ...ettings required for operating the sensor are performed with the web guide controller Information on this topic is available in the Operating Instructions for the web guide controller Before the senso...

Страница 22: ...become unusable during the operation by damages Depending on the material of the controlled web it is possible a grinding of the material web or a plane change could strike and damage the sensor or re...

Страница 23: ...off Example A Field of view partially covered by the material The left LED is lit the middle LED flickers and the right LED is off Example B Field of view completely covered by the material The two l...

Страница 24: ...reflector at regular intervals using a neutral cleaning agent and a soft cloth Keep chemical resistances in mind when choosing the cleaning agent Materials used page 9 1 Setting up the sensor again I...

Страница 25: ...e from the sensor only for sensor cables with open wire ends Personnel Qualified electrician The sensor may only be disconnected electrically by a qual ified electrician 3 Unscrew the sensor from its...

Страница 26: ...rrected It is still possible to use the sensor Error n 6 7 Only the blinking pattern of an error is displayed The sensor is no longer supplying a valid output signal Fault In the event of an error the...

Страница 27: ...et up the sensor again Check the mechanical arrangement of the sensor and reflector Is there too much reflected light present Setting up the sensor and reflector page 5 1 6 Internal setup error The er...

Страница 28: ...e humidity up to 90 non condensing Operating altitude max 3000m above sea level Materials used Housing Plastic VISTAL Protector PMMA polymethylmethacrylate glued A data sheet can be requested on this...

Страница 29: ...wer supply 4 20mA to 200 at 24V 20 28V Power supply Digital data exchange via RS 485 when connected to selected FIFE web guide controllers e g D MAXE Pin assignment Standards The DSE 15 sensor was con...

Страница 30: ...he order number When ordering replacement parts please indicate where possible Part Number Drawing Number and Model description Please be careful to keep all documents accompanying the product in a sa...

Отзывы: