3 Connecting
14
HARS series
3-1-2 AC input cable connection (2kW/3kW)
・
Connect the supplied AC input cable with crimp terminals to the input terminal L1, L2, L3,
and .
・
As for the other end of the cable without crimp terminals, attach such as crimp terminals there to
connect to a distribution board with a commertial power supply.
Be sure to electrically ground the product with the AC input terminal. It
is otherwise dangerous for the user.
・
Input voltage: 200-240Vac, 50/60Hz, three-phase
Figure1-2 AC input terminal connection
L1
L3
L2
Attach the cover to the AC input
terminal for use.